Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: This symptom will only be present if power is supplied to the endgate/liftgate window release actuator at all times or if a mechanical problem with the latch mechanism exists. | ||||
1 | Did you perform the Lift Window Release System Check? | -- | Go to Step 2 | |
2 |
Is the liftglass relay status OFF? | -- | Go to Step 6 | Go to Step 3 |
3 |
Is the liftglass relay status OFF? | -- | Go to Step 5 | Go to Step 4 |
4 | Locate and repair a short to ground in CKT 1576 (BLK). Is the repair complete? | -- | -- | |
5 | Replace the rear wiper/washer switch and endgate/liftgate window release switch. Is the repair complete? | -- | -- | |
6 | Disconnect the liftglass relay from the underhood fuse block. Will the lift glass latch? | -- | Go to Step 8 | Go to Step 7 |
7 | Locate and repair a short to power in CKT 56 (BLK/WHT). Is the repair complete? | -- | -- | |
8 | Inspect CKT 1344 (LT BLU) for a short to ground. Is a short present? | -- | Go to Step 10 | Go to Step 9 |
9 | Replace the liftglass relay in the underhood fuse block. Is the repair complete? | -- | -- | |
10 | Locate and repair the short to ground in CKT 1344 (LT BLU). Is the repair complete? | -- | -- |