Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important: The most likely causes of insufficient heating outside the heater system
include the following conditions:
| ||||||||||||||
1 | Did you perform the Heater Output Temperature Check? | -- | Go to Step 2 | |||||||||||
2 | Inspect for the following conditions:
Does the malfunction still exist? | -- | Go to Step 3 | |||||||||||
3 |
Is the airflow high? | -- | Go to Step 4 | Go to Step 7 | ||||||||||
4 | Does the airflow change with different blower motor speeds? | -- | Go to Step 5 | Go to Step 11 | ||||||||||
5 | Perform the heater output temperature check. Refer to Heater Output Temperature Check . Is the heater output temperature correct? | -- | Go to Step 6 | Go to Step 12 | ||||||||||
6 |
Is the repair complete? | -- | -- | |||||||||||
7 | Perform the function test. Refer to Function Test . Is the repair complete? | -- | System OK | Go to Step 8 | ||||||||||
8 | Inspect the airflow from the vent outlets. Is the airflow from the vent outlets high? | -- | Go to Step 9 | Go to Step 17 | ||||||||||
9 | Move the defroster and/or the vent knob to the HEATER mode. Is the defroster airflow correct? | -- | Go to Step 10 | Go to Step 18 | ||||||||||
10 |
Does the airflow change with different blower motor speeds? | -- | Go to Step 9 | Go to Step 11 | ||||||||||
11 |
Is the heater output temperature correct? | -- | Go to Step 6 | Go to Step 12 | ||||||||||
12 |
Is the temperature door fully seated to the right? | -- | Go to Step 13 | Go to Step 22 | ||||||||||
13 |
Is the air temperature around both hoses at least at the specified value? | 24°C (85°F) | Go to Step 14 | Go to Step 23 | ||||||||||
14 |
Were the hoses properly installed? | -- | Go to Step 15 | Go to Step 25 | ||||||||||
15 |
Is the air temperature around both hoses at least at the specified value? | 24°C (85°F) | Go to Step 16 | Go to Step 23 | ||||||||||
16 | Replace the heater core. Refer to Heater Core Replacement . Is the repair complete? | -- | -- | |||||||||||
17 |
Is the defroster airflow not present or low? | -- | Go to Step 18 | Go to Step 10 | ||||||||||
18 | Does the airflow change with different blower motor speeds? | -- | Go to Step 19 | Go to Step 11 | ||||||||||
19 | Inspect for airflow obstructions at the blower motor inlet and plenum. Did you find and correct a condition? | -- | Go to Step 20 | |||||||||||
20 |
Is a change in the airflow audible? | -- | Go to Step 21 | Go to Step 26 | ||||||||||
21 | Inspect for an airflow obstruction between the blower motor and the system outlets. Is the repair complete? | -- | -- | |||||||||||
22 | Inspect the coolant bypass valve for binding or damage. Did you find and correct a condition? | -- | -- | |||||||||||
23 | Inspect the thermostat for proper installation and seating. Is the thermostat properly installed and seated? | -- | Go to Step 27 | Go to Step 24 | ||||||||||
24 | Reinstall the thermostat. Is the repair complete? | -- | Go to Step 13 | -- | ||||||||||
25 | Properly reinstall the hoses. Is the repair complete? | -- | Go to Step 13 | -- | ||||||||||
26 | Inspect the following components:
Is the repair complete? | -- | -- | |||||||||||
27 | Replace the thermostat. Is the repair complete? | -- | -- |