Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Diagnostic System Check? | -- | Go to Step 2 | Go to Diagnostic System Check |
2 | Verify that the blower motor is inoperative at any speed. Does the blower motor operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Inspect the HVAC fuse in the underhood fuse block. Is the HVAC fuse open? | -- | Go to Step 4 | Go to Step 7 |
4 |
Important: The load side of the fuse is the terminal without battery voltage and the ignition switch in RUN. Is the reading less than the specified value? | 0.5 ohms | Go to Step 5 | Go to Step 6 |
5 | Repair the short to ground in CKT 540. Is the repair complete? | -- | Go to Step 22 | -- |
6 |
Does the motor operate correctly? | -- | Go to Step 22 | Go to Step 12 |
7 |
Does the test lamp light? | -- | Go to Step 8 | Go to Step 9 |
8 |
Is the reading within the specified range? | 2-4 V | Go to Step 12 | Go to Step 15 |
9 | Connect a test lamp between the blower motor connector terminal B and the battery ground. Does the test lamp light? | -- | Go to Step 11 | Go to Step 10 |
10 | Repair an open in CKT 540. Is the repair complete? | -- | Go to Step 22 | -- |
11 | Repair an open in CKT 850. Is the repair complete? | -- | Go to Step 22 | -- |
12 |
Caution: The jumpers must be of adequate gauge in order to handle the blower motor current. Does the blower motor operate at maximum speed? | -- | Go to Step 14 | Go to Step 13 |
13 | Replace the blower motor. Refer to Blower Motor and Fan Replacement . Is the replacement complete? | -- | Go to Step 22 | -- |
14 | Replace the blower motor control module. Refer to Blower Motor Control Module Replacement . Is the replacement complete? | -- | Go to Step 22 | -- |
15 | Note the readings from the scan tool. Is the reading equivalent to the specified value? | 0 V | Go to Step 16 | Go to Step 22 |
16 |
Does the test lamp light? | -- | Go to Step 17 | Go to Step 18 |
17 | Repair a short to ground in CKT 760. Is the repair complete? | -- | Go to Step 22 | -- |
18 | Connect a test lamp between the blower motor control module harness terminal A and terminal C. Does the test lamp light? | -- | Go to Step 19 | Go to Step 20 |
19 | Repair a short to battery in CKT 760. Is the repair complete? | -- | Go to Step 22 | -- |
20 | Replace the blower motor control module. Refer to Blower Motor Control Module Replacement Does the blower motor operate properly? | -- | Go to Step 22 | Go to Step 21 |
21 | Replace the ECC module. Refer to Control Assembly Replacement . Is the replacement complete? | -- | Go to Step 22 | -- |
22 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |