Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Did you review the charging system operation and perform the necessary inspections? | -- | ||||||
2 | Verify that the charge indicator is always on. Does the charge indicator operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | |||||
3 | Using the scan tool, inspect for any DTCs. Are any DTCs present? | -- | Go to the Appropriate DTC | |||||
4 |
Do all of the indicator bulbs turn ON and OFF properly? | -- | Go to Diagnostic System Check - Instrument Cluster in Instrument Panel, Gauges and Console | |||||
5 | Disconnect the generator connector. Is the battery indicator still ON? | -- | ||||||
6 |
Is continuity present? | -- | ||||||
7 | Repair the short to ground Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |||||
8 | Using the J 39200 DMM, measure the voltage at the battery stud on the generator. Is the voltage within the specified range? | 9-16 V | ||||||
9 | Repair or replace the generator Refer to Generator Replacement . Is the repair complete? | -- | -- | |||||
10 | Repair the open in CKT 2 (RED) Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |||||
11 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK |