• | Verify that the fuel level is in the same range as the customer concern. |
• | For intermittent diagnosis, refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. |
The numbers below refer to the step numbers on the diagnostic table.
This step tests for a high resistance in the signal circuit and the low reference circuit of the fuel level sensor.
DTCs will be set in the PCM (2.2L)/VCM (4.3L) when you perform this diagnostic table.
Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Instrument Cluster: Analog Schematics | ||||||||||||||
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |||||||||||
2 |
Important: Verify the J 33431-C resistance settings with a DMM. Does the fuel gage move from approximately empty to approximately full? | -- | Go to Step 4 | Go to Step 3 | ||||||||||
Important: Verify the J 33431-C resistance settings with a DMM. Important: Turn the ignition OFF momentarily between the resistance settings in order to quickly update the scan tool display. Does the Fuel Level parameter change from approximately 0 % to approximately 100 %? | -- | Go to Step 11 | Go to Step 5 | |||||||||||
4 | Inspect for the following items:
Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 7 | ||||||||||
5 | Test the signal circuit of the fuel level sensor for a high resistance. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 6 | ||||||||||
6 | Test the low reference circuit of the fuel level sensor for a high resistance. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 9 | ||||||||||
7 |
Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 8 | ||||||||||
8 |
Does the resistance change smoothly across the specified range? | 40-250 ohms | Go to Diagnostic Aids | Go to Step 10 | ||||||||||
9 | Inspect for poor connections at the harness connector of the PCM (2.2L/VCM (4.3L). Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 12 | ||||||||||
10 | Replace the fuel level sensor. Refer to the appropriate procedure:
Did you complete the replacement? | -- | Go to Step 13 | -- | ||||||||||
11 | Replace the IPC. Refer to Instrument Cluster Replacement . Did you complete the replacement? | -- | Go to Step 13 | -- | ||||||||||
12 |
Important: Program the replacement PCM/VCM. Replace the PCM/VCM. Refer to the appropriate procedure:
Did you complete the replacement? | -- | Go to Step 13 | -- | ||||||||||
Did you correct the condition? | -- | System OK | Go to Step 2 |