Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the RAP Diagnostic System Check? | -- | Go to Step 2 | |
2 | Verify that the RAP is on after timeout. Does the RAP system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Do the inputs change between ACTIVE and INACTIVE? | -- | Go to Step 4 | Go to Diagnostic System Check - Lighting Systems in Lighting Systems |
4 |
Does the RAP timer count down? | -- | Go to Step 5 | Go to Diagnostic System Check - Body Control System in Body Control System |
5 | Disconnect the body control module (BCM) connector C1. Does the RAP system deactivate? | -- | Go to Step 15 | Go to Step 6 |
6 | Disconnect the RAP relay. Does the RAP system deactivate? | -- | Go to Step 14 | Go to Step 7 |
7 | Test for a short to B+ between the RAP relay terminal 30 and the RDO IGN fuse located in the IP Fuse Block. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 8 |
8 | Remove the RDO IGN fuse from the IP Fuse Block. Did the RAP system deactivate? | -- | Go to Step 11 | Go to Step 9 |
9 | Remove the STR WHL RDO IGN fuse (if equipped) from the IP Fuse Block. Did the RAP system deactivate? | -- | Go to Step 12 | Go to Step 10 |
10 | Remove the POWER WINDOW circuit breaker from the Body Relay Block. Did the RAP system deactivate? | -- | Go to Step 13 | -- |
11 | Test for a short to B+ in CKT 1301 (DK GRN). Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 17 | -- |
12 | Test for a short to B+ in CKT 801 (DK GRN). Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 17 | -- |
13 | Test for a short to B+ in CKT 1001 (DK GRN). Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 17 | -- |
14 | Test for a short to ground between RAP relay terminal 86 and the body control module connector C1 terminal A7. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 16 |
15 | Replace the BCM. Refer to Body Control Module Replacement in Body Control System. Is the repair complete? | -- | Go to Step 17 | -- |
16 | Replace the RAP relay. Is the repair complete? | -- | Go to Step 17 | -- |
17 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |