Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 | Verify that the lock function is inoperative but the unlock function operates normally. Do the power door locks operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp light? | -- | Go to Step 5 | Go to Step 4 |
4 | Repair the open in CKT 195 (LT BLU). Refer to Wiring Repairs in wiring systems. Is the repair complete? | -- | Go to Step 6 | -- |
5 | Replace the door lock relay. Is the repair complete? | -- | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |