Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Exterior Lights Schematics | |||
1 | Did you review the Exterior Lighting Systems Description and Operation and perform the necessary inspections? | Go to Step 2 | |
2 | Verify that one or more of the repeater lamps are inoperative. Do the repeater lamps operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Do the turn signals operate correctly? | Go to Step 4 | |
4 | Test the repeater lamp front turn signal lamp supply voltage and ground circuits for an open or high resistance. Refer to Circuit Testing in Wiring Systems. Was a problem found? | Go to Step 5 | Go to Step 6 |
5 | Repair the open or high resistance in the repeater lamp front turn signal lamp supply voltage or ground circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 7 | -- |
6 | Replace the inoperative bulb or socket. Did you complete the repair? | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |