Instrument Panel Courtesy Lamp Bulb Replacement Lower
Removal Procedure
- Remove the closeout/insulator
panel. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
or
Instrument Panel Insulator Panel Replacement - Left Side
in Instrument Panel, Gages and Console.
- Remove the screw that retains the courtesy lamp socket.
- Remove the lamp from the socket.
Installation Procedure
- Install the lamp to the
socket.
- Install the courtesy lamp socket.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the courtesy
lamp socket screw.
Tighten
Tighten the socket retaining screw to 1.4 N·m (12 lb in).
- Install the insulator panel. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
or
Instrument Panel Insulator Panel Replacement - Left Side
in Instrument Panel,
Gages and Console.