The automatic transmission fluid temperature (TFT) sensor is part of the automatic transmission fluid pressure (TFP) manual valve position switch. The TFT sensor is a resistor, or thermistor, which changes value based on temperature. The sensor has a negative-temperature coefficient. This means that as the temperature increases, the resistance decreases, and as the temperature decreases, the resistance increases. The vehicle control module (VCM) supplies a 5-volt reference signal to the sensor on circuit 1227 and measures the voltage drop in the circuit. When the transmission fluid is cold, the sensor resistance is high and the VCM detects high signal voltage. As the fluid temperature warms to a normal operating temperature, the resistance becomes less and the signal voltage decreases. The VCM uses this information to control shift quality and torque converter clutch apply.
When the VCM detects one of the following unusual conditions, then DTC P0711 sets.
• | An unrealistically large change in transmission temperature |
• | A transmission temperature which remains constant for a period of time in which a measurable amount of change is expected |
DTC P0711 is a type D DTC.
• | No VSS assembly DTCs P0502 or P0503. |
• | No Transmission Component Slipping DTC P1870. |
• | The system voltage is 10-19 volts. |
• | The engine is running for 409 seconds. |
• | The vehicle speed is greater than 8 km/h (5 mph) for 409 seconds cumulative during the current ignition cycle. |
• | The TCC slip speed is greater than 120 RPM for 409 seconds cumulative during the current ignition cycle. |
• | The TFT at startup is between -40 and +21°C (-40 and +70°F). |
• | The TFT is between -38 and +151°C (-36 and +304°F). |
• | The engine coolant temperature (ECT) is greater than 70°C (158°F) and the temperature has changed by 50°C (90°F) since startup. |
DTC P0711 sets if either of the following conditions occurs:
• | The TFT does not change more than 1.50°C (2.7°F) for 409 seconds since startup. |
• | The TFT changes more than 20°C (36°F) in 200 milliseconds 14 times within 7 seconds. |
• | The VCM does not illuminate the malfunction indicator lamp (MIL). |
Important: The scan tool does not indicate the default TFT. |
Important: The actions listed below are in order of highest to lowest priority. |
• | The VCM determines a default TFT using the following matrix: |
1. | If any ECT DTCs P0117 or P0118 are set, then the default TFT is equal to 135°C (275°F). |
2. | If the ECT is 125°C (257°F) or more, then the default TFT is equal to 135°C (275°F). |
3. | If the engine run time is less than 300 seconds and: |
• | No intake air temperature (IAT) DTCs P0112 or P0113 are set and IAT is available, then the default TFT is equal to IAT. |
• | Any IAT DTCs P0112 or P0113 are set or IAT is NOT available, then the default TFT is equal to 90°C (194°F). |
4. | If the engine run time is greater than 300 seconds and no IAT DTCs P0112 or P0113 are set and IAT is available and ECT is between 40 and 125°C (104 and 257°F) and: |
• | IAT at startup is less than 15°C (59°F), then the default TFT is equal to the ECT plus 5°C (8°F). |
• | IAT at startup is greater than 35°C (95°F), then the default TFT is equal to the ECT plus 10°C (16°F). |
• | IAT at startup is between 15 and 35°C (59 and 95°F), then the default TFT is equal to the ECT. |
5. | If the engine run time is greater than 300 seconds and any IAT DTCs P0112 or P0113 are set or IAT is NOT available, then the default TFT is equal to the ECT. |
6. | If the engine run time is greater than 300 seconds and ECT is less than 40°C (104°F) or more, then the default TFT is equal to 60°C (140°F). |
• | The VCM freezes shift adapts from being updated. |
• | The VCM stores DTC P0711 in VCM history. |
• | A scan tool clears the DTC from VCM history. |
• | The VCM clears the DTC from VCM history if the vehicle completes 40 warm-up cycles without a non-emission-related diagnostic fault occurring. |
• | The VCM cancels the DTC default actions when the fault no longer exists and the ignition switch is OFF long enough in order to power down the VCM. |
Inspect the wiring at the VCM, the transmission connector and all other circuit connecting points for the following conditions:
• | A backed out terminal |
• | A damaged terminal |
• | Reduced terminal tension |
• | A chafed wire |
• | A broken wire inside the insulation |
• | Moisture intrusion |
• | Corrosion |
The numbers below refer to the step numbers on the diagnostic table.
This step tests for an intermittent short or open condition in the engine wiring harness. The test light is used as a resistor in the circuit.
This step determines if the VCM or the TFT sensor is causing a steady, unchanging TFT reading.
Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Was the Powertrain On-Board Diagnostic (OBD) System Check performed? | -- | Go to Powertrain On Board Diagnostic (OBD) System Check in Engine Controls | |||||
2 | Perform the transmission fluid checking procedure. Refer to Transmission Fluid Check . Did you perform the fluid checking procedure? | -- | Go to Transmission Fluid Check | |||||
3 |
Important: Before clearing the DTC, use the scan tool in order to record the Failure Records. Using the Clear Info function erases the Failure Records from the VCM.
Did either of the conditions occur? | -- | Go to Diagnostic Aids | |||||
4 | Did the scan tool display a condition in which the TFT does not change by more than the specified value in 409 seconds since startup? | 1.50°C (2.7°F) | ||||||
Refer to Automatic Transmission Inline Harness Connector End View . Does the TFT change by more than the specified value? | 20°C (36°F) | |||||||
Does the scan tool display the same condition as in step 4? | -- | |||||||
7 |
Important: The condition that affects this circuit may exist in other connecting branches of the circuit. Refer to Power Distribution Schematics in Wiring Systems for complete circuit distribution. Refer to General Electrical Diagnosis in Wiring Systems. Refer to Wiring Repairs in Wiring Systems. Did you find an intermittent open or short condition? | -- | ||||||
8 |
Refer to General Electrical Diagnosis in Wiring Systems. Did you find an intermittent open or short condition? | -- | ||||||
9 | Replace the A/T wiring harness assembly. Refer to TCC PWM Solenoid, TCC Solenoid, and Wiring Harness. Is the replacement complete? | -- | -- | |||||
10 | Replace the TFT sensor (this sensor is part of the TFP manual valve position switch). Refer to Valve Body and Pressure Switch Replacement. Is the replacement complete? | -- | -- | |||||
11 | Replace the VCM. Refer to VCM Replacement/Programming in Engine Controls. Is the replacement complete? | -- | -- | |||||
12 | Perform the following procedure in order to verify the repair:
Has the test run and passed? | -- | System OK |