Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Inspect the cigar lighter fuse 13 at I/P fuse block. Is the fuse functional? | -- | Go to Step 4 | Go to Step 3 |
3 | Locate and repair the overload and replace the cigar lighter fuse. Is the repair complete? | -- | Go to Step 9 | -- |
4 |
Is battery voltage present? | B+ | Go to Step 6 | Go to Step 5 |
5 | Repair the open in CKT 640 between the instrument panel fuse block and the cigar lighter. Is the repair complete? | -- | Go to Step 9 | -- |
6 | Inspect for an open in CKT 1050 (BLK) between the cigar lighter and ground G200. Did you find an open? | -- | Go to Step 7 | Go to Step 8 |
7 | Repair the open in CKT 1050 (BLK) between the cigar lighter and ground G200. Is the repair complete? | -- | Go to Step 9 | -- |
8 | Replace the cigar lighter. Is the replacement complete? | -- | Go to Step 9 | -- |
9 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |