Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION: Noise originating from the blower motor and/or the air delivery
system. No loss of battery or ground is occurring in the blower motor circuit.
The blower motor resistor and the blower motor are not exhibiting any intermittent
internal shorts. For electrical diagnosis of the blower motor circuit,
refer to
Symptoms - HVAC Systems - Manual
in
HVAC Systems - Manual.
|
1
| Did you review the Air Delivery Description and Operation
and perform the necessary inspections?
| --
| Go to
Step
2
| Go to
Symptoms - HVAC Systems - Manual
in HVAC Systems -- Manual
|
2
|
- Sit inside the vehicle.
- Close the vehicle doors and windows.
- Turn the ignition switch to ON; engine OFF.
- Turn the blower switch to position 5 (high).
- Set the temperature control to full cold.
- Set the mode control to UPPER (I/P outlets).
- Cycle through all the blower motor speeds, modes (including outside
air and recirc) and temperature control positions to determine where noise
occurs and where noise does not occur.
- Attempt to define the type of noise:
• | Tick/click, chirping, groaning, scraping |
Is a scrape or pop noise evident when selecting modes or temperature
settings (moving a mode or temperature valve)?
| --
| Go to
Step 12
| Go to
Step 3
|
3
| Is a tick/click, chirping, groaning or scraping noise present -
constantly but decreases as blower motor speed is decreased, or only at start-up/intermttent
- in all modes?
| --
| Go to
Step 6
| Go
to
Step 4
|
4
| Is an air rush/whistle noise evident in all modes but not all temperature
settings?
| --
| Go to
Step 13
| Go
to
Step 5
|
5
| Is an air rush/whistle noise evident only in defrost or lower mode?
| --
| Go to
Step 14
| Go to
Step 15
|
6
| Check for blower
motor and impeller assembly excessive vibration at each blower motor speed
by feeling the blower case.
Is excessive vibration present?
| --
| Go to
Step
7
| Go to
Step 9
|
7
|
- Remove the blower motor. Refer to
Blower Motor Replacement
.
- Examine the blower motor impeller for the following conditions:
• | Deposits of foreign material |
• | Loose impeller retainer |
• | Improper impeller alignment |
Does the blower motor impeller exhibit any of these abnormal conditions?
| --
| Go to
Step 8
| Go to
Step 9
|
8
|
- Repair or replace the blower motor impeller.
- Install the blower assembly. Refer to
Blower Motor Replacement
.
Is the action complete?
| --
| Go to
Step
16
| --
|
9
|
- Remove the blower motor. Refer to
Blower Motor Replacement
.
- Check for the presence of foreign material at the opening of the
blower intake.
Was foreign material found?
| --
| Go to
Step
11
| Go to
Step 10
|
10
|
- Replace the blower motor.
- Install the blower motor assembly. Refer to
Blower Motor Replacement
.
Is the repair complete?
| --
| Go to
Step
17
| --
|
11
|
- Remove the foreign material from the blower case.
- Repair as necessary.
Is the action complete?
| --
| Go to
Step
17
| --
|
12
|
- Remove the IP carrier. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gages and Console.
- Check the defroster, mode, air inlet and temperature door function.
- Repair or replace as necessary.
Is the action complete?
| --
| Go to
Step
17
| --
|
13
|
- Remove the I/P carrier. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gages and Console.
- Check the temperature door seals.
- Repair or replace as necessary.
Is the action complete?
| --
| Go to
Step
17
| --
|
14
|
- Remove the I/P carrier. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gages and Console.
- Check the ducts for obstructions or foreign materials.
- Remove any obstructions or foreign material found.
- Check the defroster door function.
- Repair or replace as necessary.
Is the action complete?
| --
| Go to
Step
17
| --
|
15
|
- Remove the I/P carrier. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gages and Console.
- Check the ducts for obstructions or foreign materials.
- Remove any obstructions or foreign material found.
- Check the defroster door seals.
- Repair or replace as necessary.
Is the action complete?
| --
| Go to
Step
17
| --
|
16
|
- Turn OFF the ignition switch.
- Reconnect or install any connectors or components which were disconnected
or removed.
- Recheck for the presence of blower motor/air delivery system noise.
Is the noise still present?
| --
| Go to
Step
10
| System OK
|
17
|
- Turn OFF the ignition switch.
- Reconnect or install any connectors or components which were disconnected
or removed.
- Recheck for the presence of blower motor/air delivery system noise.
Is the noise still present?
| --
| Go to
Step
2
| System OK
|