The numbers below refer to the step numbers on the diagnostic table.
This step tests for a blower motor that does not operate regardless of the desired blower motor speed.
This step tests for a blower motor that operates, yet does not accurately respond to the desired blower motor speed.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: Air does not flow correctly from the air distribution outlets. | ||||
1 | Did you review the HVAC operation and perform the necessary inspections? | -- | Go to Step 2 | |
2 |
Is the blower motor OFF? | -- | Go to Step 3 | Go to Blower Motor Always On |
Place the blower control in each speed position. Does the blower motor operate at all? | -- | Go to Step 4 | Go to Blower Motor Inoperative | |
Does the blower motor operate correctly for each speed position? | -- | Go to Step 5 | Go to Blower Motor Malfunction | |
5 | Is the HVAC control assembly mode selection inoperative in all positions? | -- | Go to Testing for Intermittent Conditions and Poor Connections |