Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the HVAC Blower Controls System Check? | -- | Go to Step 2 | |
2 | Inspect the HTR-A/C fuse 12 at the IP fuse block. Is the fuse operational? | -- | Go to Step 4 | Go to Step 3 |
3 |
Is the repair complete? | -- | -- | |
4 |
Does the blower motor operate? | Go to Step 5 | ||
5 |
Did the test lamp light? | -- | Go to Step 6 | Go to Step 7 |
6 | Replace the front blower motor. Refer to Blower Motor and Fan Replacement . Is the repair complete? | -- | -- | |
7 | Connect a test lamp J 35616-200 from the front blower motor connector CKT 65 (PPL) cavity A to ground. Did the test lamp light? | -- | Go to Step 8 | Go to Step 9 |
8 |
Is there continuity? | -- | Go to Step 10 | Go to Step 11 |
9 |
Did the test lamp light? | -- | Go to Step 13 | Go to Step 12 |
10 | Inspect CKT 350 (BLK) for an open between the front blower motor and the blower motor resistor and relay pack. Does an open exist? | -- | Go to Step 14 | Go to Step 15 |
11 | Repair the open in CKT 350 (BLK) between ground G100 and the blower motor resistor and relay pack. Is the repair complete? | -- | -- | |
12 | Repair the open in CKT 141 (ORN) between the HVAC control module and the instrument fuse block. Is the repair complete? | -- | -- | |
13 |
Did the test lamp light? | -- | Go to Step 17 | Go to Step 16 |
14 | Repair the open in CKT 350 (BLK) between the front blower motor and the blower motor resistor and relay pack. Is the repair complete? | -- | -- | |
15 | Replace the blower motor resistor and relay pack. Refer to Blower Motor Resistor Replacement . Is the repair complete? | -- | -- | |
16 | Replace the HVAC control module. Refer to Control Assembly Replacement . Is the repair complete? | -- | -- | |
17 | Use a test lamp J 35616-200 in order to backprobe from the HVAC control module connector C3 CKT 119 (WHT) cavity A to ground. Did the test lamp light? | -- | Go to Step 19 | Go to Step 18 |
18 | Repair the open in CKT 119 (WHT) between the connector C2 cavity G and the connector C3 cavity A of the HVAC control module. Is the repair complete? | -- | -- | |
19 |
Did the test lamp light? | -- | Go to Step 15 | Go to Step 16 |