Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Exterior Lights System Check? | -- | Go to Step 2 | |
2 |
Do the stoplamps light? | -- | Go to Step 3 | Go to Hazard Lamps Inoperative |
3 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 5 |
4 | Connect a fused jumper from the TCC/stoplamp switch CKT 17 (WHT) cavity A to CKT 140 (ORN) cavity B Do the stoplamps light? | -- | Go to Step 6 | Go to Step 7 |
5 | Locate and repair the open on CKT 140 (ORN) between the TCC/stoplamp switch and splice S201. Is the repair complete? | -- | -- | |
6 | Replace the TCC/stoplamp switch. Is the repair complete? | -- | -- | |
7 | Inspect for an open in CKT 17 (WHT) between the TCC/stoplamp switch and the turn/hazard switch. Is the wiring OK? | -- | Go to Step 8 | Go to Step 9 |
8 | Replace the turn/hazard switch. Is the repair complete? | -- | -- | |
9 | Repair the open to CKT 17 (WHT) between the TCC/stoplamp switch and the turn/hazard switch. Is the repair complete? | -- | -- |