Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Locks System Check? | -- | Go to Step 2 | |
2 | Use a test lampJ 35616-200 in order to backprobe CKT 640 (ORN) cavity B or cavity F at the inoperative door lock switch to ground. Does the test lamp light? | -- | Go to Step 4 | Go to Step 3 |
3 | Repair the open in CKT 640 (ORN) between the inoperative door lock switch and splice S223. Is the repair complete? | -- | -- | |
4 |
Does the test lamp light? | -- | Go to Step 6 | Go to Step 5 |
5 | Replace the inoperative door lock switch. Is the repair complete? | -- | -- | |
6 |
Does the test lamp light? | -- | Go to Step 11 | Go to Step 5 |
7 | Operate the inoperative door lock switch in both the LOCK and the UNLOCK positions. Is the LOCK position still inoperative? | -- | Go to Step 8 | Go to Step 9 |
8 | Repair the open in CKT 195 (LT BLU) between the inoperative door lock switch and splice S232. Is the repair complete? | -- | -- | |
9 | Operate the inoperative door lock switch in both the LOCK and the UNLOCK position. Is the UNLOCK position still inoperative? | -- | Go to Step 10 | Go to Step 11 |
10 | Repair the open in CKT 194 (WHT) between the inoperative door lock switch and splice S231. Is the repair complete? | -- | -- | |
11 | Operate the inoperative door lock switch in both the LOCK and the UNLOCK positions. Are both the LOCK and the UNLOCK positions still inoperative? | -- | Go to Step 5 | Go to Step 7 |