An 8 digit part identification number is on a mylar label affixed to the fuel meter body assembly. Refer to this number if servicing or part replacement is required.
J 34730-1A fuel pressure gauge
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to the vehicle or its components.
Notice: Do not use any solvent that contains Methyl Ethyl Ketone (MEK). This solvent may damage fuel system components.
Notice: Cover the injector sockets in order to prevent dirt and other contaminants from entering the open fuel passages.
Important: When disconnecting the poppet nozzles, remember the sequence in order to ensure correct poppet nozzle placement to each cylinder.
Caution: Verify that the poppet nozzles are firmly seated and locked in their casting sockets in order to reduce the risk of fire and personal injury. An unlocked poppet nozzle could work loose from its socket and produce a fuel leak.
Important: The fuel meter body assemblies are numbered to indicate poppet nozzle order.
8.1. | Turn ON the ignition for 2 seconds. |
8.2. | Turn ON the ignition for 10 seconds. |
8.3. | Turn ON the ignition . |
8.4. | Inspect for fuel leaks. |