Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Important: Inspect for inoperative bulbs before beginning diagnostic procedure. | ||||||||||
1 | Did you perform the Lighting Diagnostic System Check? | -- | Go to Step 2 | |||||||
2 |
Does the test lamp light? | -- | Go to Step 3 | Go to Step 5 | ||||||
3 | Inspect the condition of the lamp socket and check for the following possible conditions:
Is the lamp socket in proper condition? | -- | Go to Step 4 | Go to Step 6 | ||||||
4 | Repair the open in CKT 1350 (BLK) or CKT 1450 (BLK) between the inoperative left side or right side backup lamp and ground G400 or ground G401 respectively. Is the repair complete? | -- | Go to Step 7 | -- | ||||||
5 | Repair the open in CKT 24 (LT GRN) between the inoperative lamp and splice S321. Is the repair complete? | -- | Go to Step 7 | -- | ||||||
6 | Replace the lamp socket. Is the repair complete? | -- | Go to Step 7 | -- | ||||||
7 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |
Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
Important: Inspect for inoperative bulbs before beginning diagnostic procedure. | ||||||||
1 | Did you perform the Lighting Diagnostic System Check? | -- | Go to Step 2 | |||||
2 |
Does the test lamp light? | -- | Go to Step 3 | Go to Step 4 | ||||
3 |
Is repair complete? | -- | Go to Step 5 | -- | ||||
4 | Locate and repair open in LT GRN (24) wire between inoperative lamp and S410. Is the repair complete? | -- | Go to Step 5 | -- | ||||
5 | Operate the system in order to verify the repair. Did you correct the condition. | -- | System OK | Go to Step 2 |