Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Important: The 9 CKT (BRN) is monitored by the BCM, and will set a code if a short-to-ground occurs within the 9 CKT (BRN). Check for inoperative bulbs before beginning diagnostic procedure. | ||||||||||||
1 | Did you perform the Lighting Diagnostic System Check? | -- | Go to Step 2 | |||||||||
2 | Turn the headlamp and panel dimmer switch to the PARK position. Are all of the component illumination lamps inoperative? | -- | Go to Step 3 | Go to Step 4 | ||||||||
3 | Use a test lamp in order to backprobe from the headlamp and panel dimmer switch CKT 9 (BRN) cavity S to ground. Does the test lamp light? | -- | Go to Step 7 | Go to Step 8 | ||||||||
4 | Inspect for an open in the following locations:
Did you find any opens? | -- | Go to Step 5 | Go to Step 6 | ||||||||
5 | Repair the open in the following locations:
Are the repairs complete? | -- | Go to Step 9 | -- | ||||||||
6 | Replace the affected lamps. Are the replacements complete? | -- | Go to Step 9 | -- | ||||||||
7 | Repair the open in CKT 9 (BRN) between splice S217 and the headlamp and panel dimmer switch. Is the repair complete? | -- | Go to Step 9 | -- | ||||||||
8 | Replace the headlamp and panel dimmer switch Headlamp Switch Replacement . Is the replacement complete? | -- | Go to Step 9 | -- | ||||||||
9 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |