Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the Stationary Windows Description and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Disconnect the RR defog fuse. Did the rear window defogger grid turn off? | -- | Go to Step 4 | Go to Step 3 |
3 | Locate and repair short to power in CKT 1093. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 7 | -- |
4 |
Did the rear window defogger grid turn off? | -- | Go to Step 6 | Go to Step 5 |
5 | Locate and repair short to power in CKT 293. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 7 | -- |
6 | Replace the Heater and A/C Control Module. Refer to Control Assembly Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | -- | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |