Table 1: | A/C Performance Table |
Table 2: | A/C Performance Table With Rear A/C |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F), 345 kPa (50 psi) More than 24°C (75°F), 483 kPa (70 psi) More than 33°C (90°F), 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 4 | Go to Step 3 | |||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-18°C (55-65°F) | 0-100% | 131-172 kPa (19-25 psi) | 1000-1276 kPa (135-175 psi) | 4°C (40°F) |
19-24°C (66-75°F) | Below 40% | 165-207 kPa (24-30 psi) | 1103-1379 kPa (160-200 psi) | 7°C (44°F) |
Above 40% | 165-207 kPa (24-30 psi) | 1172-1448 kPa (170-210 psi) | 7°C (44°F) | |
25-29°C (76-85°F) | Below 35% | 179-221 kPa (26-32 psi) | 1310-1586 kPa (190-230 psi) | 8°C (47°F) |
35-60% | 200-241 kPa (29-35 psi) | 1344-1620 kPa (195-235 psi) | 10°C (50°F) | |
Above 60% | 207-248 kPa (30-36 psi) | 1344-1620 kPa (195-235 psi) | 11°C (51°F) | |
30-35°C (86-95°F) | Below 30% | 234-276 kPa (34-40 psi) | 1620-1896 kPa (235-275 psi) | 12°C (54°F) |
30-50% | 262-303 kPa (38-44 psi) | 1793-2068 kPa (260-300 psi) | 16°C (60°F) | |
Above 50% | 276-324 kPa (40-47 psi) | 1793-2068 kPa (260-300 psi) | 16°C (60°F) | |
36-41°C (96-105°F) | Below 20% | 262-317 kPa (38-46 psi) | 1793-2068 kPa (260-300 psi) | 15°C (59°F) |
20-40% | 255-310 kPa (37-45 psi) | 1586-1862 kPa (230-270 psi) | 14°C (57°F) | |
Above 40 % | 296-352 kPa (43-51 psi) | 1999-2275 kPa (290-330 psi) | 17°C (63°F) | |
42-46°C (106-115°F) | Below 20% | 262-317 kPa (38-46 psi) | 1758-2034 kPa (255-295 psi) | 15°C (59°F) |
Above 20% | 269-324 kPa (39-47 psi) | 1758-2034 kPa (255-295 psi) | 16°C (60°F) | |
47-49°C (116-120°F) | Below 30% | 296-352 kPa (43-51 psi) | 1931-2206 kPa (280-320 psi) | 18°C (64°F) |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Rear Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-18°C (55-65°F) | 0-100% | 131-172 kPa (19-25 psi) | 1000-1276 kPa (135-175 psi) | 4°C (40°F) |
19-24°C (66-75°F) | Below 40% | 165-207 kPa (24-30 psi) | 1103-1379 kPa (160-200 psi) | 7°C (44°F) |
Above 40% | 165-207 kPa (24-30 psi) | 1172-1448 kPa (170-210 psi) | 7°C (44°F) | |
25-29°C (76-85°F) | Below 35% | 179-221 kPa (26-32 psi) | 1310-1586 kPa (190-230 psi) | 8°C (47°F) |
35-60% | 200-241 kPa (29-35 psi) | 1344-1620 kPa (195-235 psi) | 10°C (50°F) | |
Above 60% | 207-248 kPa (30-36 psi) | 1344-1620 kPa (195-235 psi) | 11°C (51°F) | |
30-35°C (86-95°F) | Below 30% | 234-276 kPa (34-40 psi) | 1620-1896 kPa (235-275 psi) | 12°C (54°F) |
30-50% | 262-303 kPa (38-44 psi) | 1793-2068 kPa (260-300 psi) | 16°C (60°F) | |
Above 50% | 276-324 kPa (40-47 psi) | 1793-2068 kPa (260-300 psi) | 16°C (60°F) | |
36-41°C (96-105°F) | Below 20% | 262-317 kPa (38-46 psi) | 1793-2068 kPa (260-300 psi) | 15°C (59°F) |
20-40% | 255-310 kPa (37-45 psi) | 1586-1862 kPa (230-270 psi) | 14°C (57°F) | |
Above 40% | 296-352 kPa (43-51 psi) | 1999-2275 kPa (290-330 psi) | 17°C (63°F) | |
42-46°C (106-115°F) | Below 20% | 262-317 kPa (38-46 psi) | 1758-2034 kPa (255-295 psi) | 15°C (59°F) |
Above 20% | 269-324 kPa (39-47 psi) | 1758-2034 kPa (255-295 psi) | 16°C (60°F) | |
47-49°C (116-120°F) | Below 30% | 296-352 kPa (43-51 psi) | 1931-2206 kPa (280-320 psi) | 18°C (64°F) |