Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Was the Hydraulic Brake System Diagnostic Check performed? | -- | ||||||||||
2 | Perform the Accumulator Leak-Down test. Refer to Accumulator Leak-Down Test . Did the accumulator pass the leak-down test? | -- | ||||||||||
3 | Replace the accumulator. Refer to Power Brake Booster Replacement . Is the repair complete? | -- | -- | |||||||||
4 | Inspect the following power steering system components for comtamination:
Is the power steering system fluid contaminated? | -- | ||||||||||
5 |
Is the repair complete? | -- | -- | |||||||||
6 | Replace the hydraulic brake booster. Refer to Power Brake Booster Replacement . Is the repair complete? | -- | -- | |||||||||
7 | Verify the proper brake system operation. Does the original condition still exist? | -- | Go to Step 8 | |||||||||
8 | Verify customer complaint. Has the customer complaint been verified? | -- | Go to Step 1 |