Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Interior Lights Dimming System Check performed? | -- | Go to Step 2 | |
2 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 3 |
3 | Repair the open in CKT 8 (GRY) between splice S223 and the instrument cluster. Do the IP lamps dim? | -- | Go to Step 4 | |
4 | Connect a J 39200 DMM between the instrument cluster connector, cavity B1 for CKT 150 (BLK), and ground. Is continuity present? | -- | Go to Step 5 | Go to Step 6 |
5 | Replace the instrument cluster. Do the IP lamps dim? | -- | -- | |
6 | Repair the open in CKT 150 (BLK) between ground G201 and the instrument cluster. Do the IP lamps dim? | -- | -- |