Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Headlamp Leveling System Check performed? | -- | Go to Step 2 | |
2 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 3 |
3 | Repair the open in CKT 39 (PNK) between the headlamp leveling switch and the IP fuse block. Is the repair complete? | -- | -- | |
4 |
Does the test lamp light? | -- | Go to Step 6 | Go to Step 5 |
5 | Repair the open in CKT 39 (PNK) between the headlamp levelling actuator and the IP fuse block. Is the repair complete? | -- | -- | |
6 | Connect an unpowered test lamp between the headlamp leveling switch connector cavity 31A for CKT 150/350 (BLK) and connector cavity 56B for CKT 39 (PNK). Does the test lamp light? | -- | Go to Step 8 | Go to Step 7 |
7 | Locate and repair the open in CKT 350 (BLK) between cavity 31A of the headlamp leveling actuator connector and G201. Is the repair complete? | -- | -- | |
8 | Connect an unpowered test lamp between cavity 1 of the headlamp leveling actuator connector on CKT 150/350 (BLK) and connector cavity 3 on CKT 39 (PNK). Does the test lamp light? | -- | Go to Step 10 | Go to Step 9 |
9 | Locate and repair the open in CKT 350 (BLK) between cavity 1 of the headlamp leveling actuator connector and splice S205. Is the repair complete? | -- | -- | |
10 | Connect a J 39200 DMM to CKT 189 (DK GRN) between cavity G of the headlamp leveling switch connector and cavity 2 headlamp leveling actuator connector. Is continuity present? | -- | Go to Step 11 | Go to Step 12 |
11 | Replace the headlamp leveling switch. Is the repair complete? | -- | -- | |
12 | Repair the open in CKT 189 (DK GRN) between the headlamp leveling switch and splice S151. Is the repair complete? | -- | -- |