Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Was the Exterior Lights System Check performed? | -- | Go to Step 2 | |||||
2 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 3 | ||||
3 | Locate and repair the open in CKT 139 (PNK) between the IP fuse block and C200. Is the repair complete? | -- | -- | |||||
4 |
Is continuity present? | -- | Go to Step 6 | Go to Step 5 | ||||
5 |
Is the repair complete? | -- | -- | |||||
6 | Connect a J 39200 DMM between connector C200 cavity E9 of CKT 1697 (PPL) and ground. Is continuity present? | -- | Go to Step 7 | Go to Step 8 | ||||
7 |
Is the repair complete? | -- | -- | |||||
8 |
Is continuity present? | -- | Go to Step 10 | Go to Step 9 | ||||
9 |
Is the repair complete? | -- | -- | |||||
10 |
Is continuity present? | -- | Go to Step 12 | Go to Step 11 | ||||
11 | Locate and repair the open in CKT 1508 (LT BLU) between connector C200 and the turn/hazard lamp flasher. Is the repair complete? | -- | -- | |||||
12 | Connect a J 39200 DMM between connector C200 pin E9 on CKT 16 (PPL) and ground. Is continuity present? | -- | Go to Step 13 | Go to Step 14 | ||||
13 | Locate and repair the short to ground in CKT 16 (PPL) between the turn/hazard lamp flasher and connector C200. Is the repair complete? | -- | -- | |||||
14 | Connect a J 39200 DMM between connector C200 pin E9 on CKT 16 (PPL) and the turn/hazard lamp flasher connector cavity B7. Is continuity present? | -- | Go to Step 16 | Go to Step 15 | ||||
15 | Locate and repair the open in CKT 16 (PPL) between the turn/hazard lamp flasher and connector C200. Is the repair complete? | -- | -- | |||||
16 | Connect a J 39200 DMM between turn/hazard lamp flasher connector cavity C8 on CKT 150 (BLK) and ground. Is continuity present? | -- | Go to Step 16 | Go to Step 16 | ||||
17 | Replace the turn/hazard lamp flasher. Is the repair complete? | -- | -- | |||||
18 | Locate and repair the open in CKT 150 (BLK) between the turn/hazard lamp flasher and G201. Is the repair complete? | -- | -- |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Exterior Lights System Check performed? | -- | Go to Step 2 | |
2 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 3 |
3 | Locate and repair the open in CKT 139 (PNK) between the IP fuse block and C200. Is the repair complete? | -- | -- | |
4 |
Is continuity present? | -- | Go to Step 6 | Go to Step 5 |
5 |
Is the repair complete? | -- | -- | |
6 | Connect a J 39200 DMM between connector C200 cavity E9 of CKT 1697 (PPL) and ground. Is continuity present? | -- | Go to Step 7 | Go to Step 8 |
7 |
Is the repair complete? | -- | -- | |
8 |
Is continuity present? | -- | Go to Step 10 | Go to Step 9 |
9 |
Is the repair complete? | -- | -- | |
10 |
Is continuity present? | -- | Go to Step 12 | Go to Step 11 |
11 | Locate and repair the open in CKT 1508 (LT BLU) between connector C200 and the turn/hazard lamp flasher. Is the repair complete? | -- | -- | |
12 | Connect a J 39200 DMM between connector C200 pin E9 on CKT 16 (PPL) and the turn/hazard lamp flasher connector cavity B7. Is continuity present? | -- | Go to Step 13 | Go to Step 14 |
13 | Locate and repair the short to ground in CKT 16 (PPL) between the turn/hazard lamp flasher and connector C200. Is the repair complete? | -- | -- | |
14 | Connect a J 39200 DMM between connector C200 pin E9 on CKT 16 (PPL) and ground. Is continuity present? | -- | Go to Step 16 | Go to Step 15 |
15 | Locate and repair the open in CKT 16 (PPL) between the turn/hazard lamp flasher and connector C200. Is the repair complete? | -- | -- | |
16 | Connect a J 39200 DMM between turn/hazard lamp flasher connector cavity C8 on CKT 150 (BLK) and ground. Is continuity present? | -- | Go to Step 16 | Go to Step 16 |
17 | Replace the turn/hazard lamp flasher. Is the repair complete? | -- | -- | |
18 | Locate and repair the open in CKT 150 (BLK) between the turn/hazard lamp flasher and G201. Is the repair complete? | -- | -- |