Step
| Action
| Value(s)
| Yes
| No
|
1
| Was the Audible Warnings System Check performed?
| --
| Go to
Step 2
| Go to
Audible Warnings System Check
|
2
|
- Place the ignition switch in the RUN position.
- Disconnect the connector at the multi-function alarm module.
- Disconnect the connector at the instrument cluster.
- Connect an unpowered test lamp between the multi-function alarm
module connector, cavity C2 for CKT 234 (YEL), and ground.
Does the test lamp light?
| --
| Go to
Step 3
| Go to
Step 4
|
3
| Repair the short to voltage in CKT 234 (YEL) between the multi-function
alarm module and the instrument cluster.
Does the fasten safety belt indicator remain illuminated?
| --
| Go to
Step 4
| Go to
Audible Warnings System Check
|
4
|
- Reconnect the connector at the multi-function alarm module.
- Connect an unpowered test lamp between the instrument cluster
connector, cavity A12 for CKT 234 (YEL), and ground.
Does the test lamp light?
| --
| Go to
Step 5
| Go to
Step 6
|
5
| Replace the multi-function alarm module.
Does the fasten safety belt indicator remain illuminated?
| --
| Go to
Step 6
| Go to
Audible Warnings System Check
|
6
| Replace the instrument cluster.
Does the fasten safety belt indicator remain illuminated?
| --
| Go to
Audible Warnings System Check
| --
|
Step
| Action
| Value(s)
| Yes
| No
|
1
| Was the Audible Warnings System Check performed?
| --
| Go to
Step 2
| Go to
Audible Warnings System Check
|
2
|
- Turn the ignition switch to the RUN position.
- Disconnect the connector C1 at the multifunction alarm
module.
- Disconnect the connector at the instrument cluster.
- Connect an unpowered test lamp between the following components:
• | The multifunction alarm module connector C1 cavity C2
for the CKT (YEL) wire |
Did the test lamp light?
| --
| Go to
Step 3
| Go to
Step 4
|
3
|
- Locate the short to voltage in the CKT 234 (YEL)
wire between the following components:
• | The multifunction alarm module |
- Repair the short to voltage in the CKT 234 (YEL)
wire between the following components:
• | The multifunction alarm module |
Is the repair complete?
| --
| Go to
Audible Warnings System Check
| --
|
4
|
- Connect the connector C1 at the multifunction alarm module.
- Connect an unpowered test lamp between the following components:
• | The instrument cluster connector cavity A12
for the CKT 234 (YEL) wire |
Did the test lamp light?
| --
| Go to
Step 5
| Go to
Step 6
|
5
| Replace the multifunction alarm module.
Is the repair complete?
| --
| Go to
Audible Warnings System Check
| --
|
6
| Replace the instrument cluster.
Is the repair complete?
| --
| Go to
Audible Warnings System Check
| --
|