Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Is continuity present? | -- | Go to Step 2 | Go to Step 3 |
2 | Replace the multi-function alarm module. Refer to Multifunction Alarm Module Replacement . Is the repair complete? | -- | -- | |
3 | Repair the open in CKT 39 (PNK) between splice S216 and the multi-function alarm module. Is the repair complete? | -- | -- |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Audible Warnings System Check performed? | -- | ||
2 |
Is continuity present? | -- | ||
3 | Replace the multi-function alarm module. Is the repair complete? | -- | -- | |
4 | Repair the open in either CKT 39 (PNK) between the IP fuse block and the multi-function alarm module. Is the repair complete? | -- | -- |