Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the test lamp light? | -- | Go to Step 2 | Go to Step 3 |
2 | Replace the multi-function alarm module. Refer to Multifunction Alarm Module Replacement . Is the repair complete? | -- | -- | |
3 | Repair the open in CKT 8 (GRY) between splice S223 and the multi-function alarm module. Is the repair complete? | -- | -- |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Audible Laryngitis System Check performed? | -- | ||
2 |
Does the test lamp light? | -- | ||
3 | Replace the multi-function alarm module. Is the repair complete? | -- | -- | |
4 | Repair the open in either CKT 8 (GRY) between the IP dimmer switch and the multi-function alarm module or in CKT 44 (DK GRN) between the IP dimmer switch and ILLUM fuse 14. Is the repair complete? | -- | -- |