When you first turn the ignition switch to the RUN position, the inflatable restraint sensing and diagnostic module (SDM) performs tests to diagnose critical malfunctions within the SDM. Upon passing these tests the following circuits are measured to ensure that they are within their respective normal voltage ranges:
• | IGNITION 1 |
• | 23 VLR |
• | Deployment loop voltages |
The SDM monitors the voltages at DRIVER SIDE LOW terminal 3 and PASSENGER SIDE LOW terminal 4 to detect shorts to ground in the inflator module circuits. The service wait time is 10 minutes. Refer to SIR Service Precautions .
• | The driver and passenger deployment loops are not open. |
• | The driver deployment loop is not shorted to voltage. |
• | The voltage at DRIVER SIDE LOW terminal 3 is more than 3.3 volts. |
• | The voltage at PASSENGER SIDE LOW terminal 4 is less than 3.3 volts for 500 milliseconds. |
The following tests inspect for this DTC. These tests occur when IGNITION 1 is within the normal operating voltage range.
• | POWER-ON--When the malfunction is detected in this test, the RESISTANCE MEASUREMENT test will not be performed. |
• | CONTINUOUS MONITORING |
• | The SDM sets DTC B1018. |
• | The SDM sets DTC B1071 |
• | The SDM turns ON the AIR BAG warning lamp. |
DTC B1018 is a latched code. You may not clear a latched code. Repair the malfunction that set this DTC before you replace the SDM.
A short to ground in the inflatable restraint IP module circuit may cause an intermittent condition. A DTC B1018 would be accompanied by DTC B1071. Inspect CKT 1403 and CKT 1404 carefully for cut or chafed wires. Wiring pigtail damage requires replacement of the inflatable restraint IP module. A careful inspection of the circuits and components indicated on the DTC B1018 table is essential in order to prevent damage to the replacement inflatable restraint sensing and diagnostic module (SDM). The diagnostic table directs the technician to note the entry value of PASSENGER SENSELO. Comparing the value of PASSENGER SENSELO may be helpful in determining if an intermittent condition exists.
When measurements are requested in this table, use the J 39200 DMM with the correct terminal adapter from the J 35616 Connector Test Adapter Kit. When an inspection for proper connection is requested, refer to Testing for Electrical Intermittents in Wiring Systems. When a wire, connector or terminal repair is requested, use the J-38125 Terminal Repair Kit and refer to Wiring Repairs in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table:
This test determines the passenger side low voltage which is measured by the inflatable restraint sensing and diagnostic module (SDM). A reading of 3.3 V or more indicates that an intermittent condition may exist.
This test isolates the malfunction to one side of the inflatable restraint IP module yellow 2-way connector.
This test determines whether the malfunction is in CKT 1403.
This test determines whether the malfunction is in CKT 1404.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Notice: When DTC B1018 or B1024 has been set it is necessary to replace the inflatable restraint Sensing and Diagnostic Module (SDM). Setting DTC B1018 or B1024 will also cause DTC B1071 to set. When a scan tool clear codes command is issued and the malfunction is no longer present, DTC B1018 or B1024 and DTC B1071 will remain current. Make sure that the short to ground condition is repaired prior to installing a replacement SDM to avoid damaging the SDM. | ||||
1 | Was the SIR Diagnostic System Check performed? | -- | Go to Step 2 | |
Is the PASSENGER SENSELO less than the specified value? | 3.3 V | Go to Step 3 | Refer to Diagnostic Aids | |
Is PASSENGER SENSELO less than the specified value? | 3.3 V | Go to Step 5 | Go to Step 4 | |
4 |
Is the repair complete? | -- | Go to Step 9 | -- |
Is the resistance less than the specified value? | OL | Go to Step 6 | Go to Step 7 | |
6 | Repair a short to ground condition in CKT 1403. Is the repair complete? | -- | Go to Step 9 | -- |
Measure the resistance on the SDM harness connector from terminals 4 circuit to 6 circuit. Is the resistance less than the specified value? | OL | Go to Step 8 | ||
8 | Repair a short to ground condition in CKT 1404. Is the repair complete? | -- | Go to Step 9 | -- |
9 |
Have all the SIR components been reconnected and properly mounted? | 3.3 V | -- |