When you first turn the ignition switch to the RUN position, the inflatable restraint sensing and diagnostic module (SDM) performs tests to diagnose critical malfunctions within the SDM. Upon passing these tests the following circuits are measured to ensure that they are within their respective normal voltage ranges:
• | IGNITION 1 |
• | 23 VLR |
• | Deployment loop voltages |
The SDM monitors the voltages at DRIVER SIDE LOW terminal 3 and PASSENGER SIDE LOW terminal 4 to detect shorts-to-B+ in the inflator module circuits.
• | The voltage at PASSENGER SIDE LOW terminal 4 is less than 4.8 volts. |
• | The voltage at DRIVER SIDE LOW terminal 3 is more than 4.8 volts for 500 milliseconds. |
The CONTINUOUS MONITORING test inspects for this DTC. This test occurs when IGNITION 1 is within the normal operating voltage range.
• | The SDM sets a diagnostic trouble code. |
• | The SDM turns ON the AIR BAG warning lamp. |
• | Current DTC--The voltage at DRIVER SIDE LOW terminal 3 is less than 4.8 volts for 500 milliseconds. |
• | History DTC |
- | You issue a scan tool CLEAR CODES command |
- | After 250 malfunction free ignition cycles have occurred |
A short to B+ in the inflatable restraint steering wheel module circuit may cause an intermittent condition. Inspect CKT 347 and CKT 348 carefully for cut or chafed wires. The diagnostic table directs the technician to note the entry value of DRIVER SENSELO. Comparing the value of DRIVER SENSELO may be helpful in determining if an intermittent condition exists.
When measurements are requested in this table, use the J 39200 DMM with the correct terminal adapter from the J 35616 Connector Test Adapter Kit. When an inspection for proper connection is requested, refer to Testing for Electrical Intermittents in Wiring Systems. When a wire, connector or terminal repair is requested, use the J-38125 Terminal Repair Kit and refer to Wiring Repairs in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table:
This test determines the driver side low voltage which is measured by the inflatable restraint sensing and diagnostic module (SDM).
This test isolates the malfunction to one side of the inflatable restraint steering wheel module coil yellow 2-way connector.
This test determines whether the malfunction is due to the inflatable restraint steering wheel module or the module coil.
This test determines whether the malfunction is in CKT 347.
This test determines whether the malfunction is in CKT 348.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the SIR Diagnostic System Check performed? | -- | Go to Step 2 | |
Has the DRIVER SENSELO been read and recorded on the repair order? | -- | Go to Step 3 | -- | |
Is DRIVER SENSELO more than the specified value? | 4.8 V | Go to Step 7 | Go to Step 4 | |
Is DRIVER SENSELO more than the specified value? | 4.8 V | Go to Step 6 | Go to Step 5 | |
5 |
Is the repair complete? | -- | Go to Step 11 | -- |
6 |
Is the repair complete? | -- | Go to Step 11 | -- |
Is the measured voltage equal to the specified value? | 0.0 V | Go to Step 9 | Go to Step 8 | |
8 |
Is the repair complete? | -- | Go to Step 11 | -- |
Measure the voltage on the SDM harness connector from terminal 3 circuit to terminal 6 circuit. Is the measured voltage equal to the specified value? | 0.0 V | Go to Step 10 | ||
10 |
Is the repair complete? | -- | Go to Step 11 | -- |
11 |
Have all the SIR components been reconnected and properly mounted? | -- | Go to Step 12 | -- |
12 | Clear all the SIR DTCs. Have all the SIR DTCs been cleared? | -- | -- |