Step | Action | Value(s) | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Diagnostic System Check for Starting and Charging? | -- | Go to Step 2 | |||||||||||||
2 | Start the engine, observe the charge indicator on the instrument cluster (IPC) [or message center (DIC)]. Does the charge indicator illuminate [or message center (DIC) display a charging system message]? | -- | Go to Step 3 | |||||||||||||
3 |
Important: The green POWER lamp of the tester should remain illuminated while the tester is being used.
Connect the red lead of the J 41450-B Generator Electronic Tester to the generator output terminal. Does the green POWER lamp on the tester illuminate? | -- | Go to Step 6 | Go to Step 4 | ||||||||||||
4 | Measure the voltage from the output terminal of the generator to the generator metal housing. Does the voltage measure equal to the specified value? | B + | Go to Step 14 | Go to Step 5 | ||||||||||||
5 | Measure the voltage from the output terminal of the generator to the battery negative terminal. Does the voltage measure equal to the specified value? | B + | Go to Step 12 | Go to Step 11 | ||||||||||||
6 |
Caution: Batteries produce explosive gases. Batteries contain corrosive acid.
Batteries supply levels of electrical current high enough to cause burns.
Therefore, in order to reduce the risk of personal injury while working
near a battery, observe the following guidelines:
Turn OFF completely the load tool before connecting or disconnecting a carbon pile load tester to the battery. Otherwise, sparking at the terminals could cause battery gasses to explode and cause personal injury.
Important: Ensure that all generator output circuit wires pass through the inductive probe. Does the red DIAGNOSTIC lamp on the tester illuminate? | -- | Go to Step 7 | Go to Step 13 | ||||||||||||
7 |
Does the red DIAGNOSTIC lamp on the tester illuminate? | -- | Go to Step 15 | Go to Step 8 | ||||||||||||
8 |
Important: If the generator is not capable of producing the Load Test amps, operate the generator at it's maximum possible output. Does the red DIAGNOSTIC lamp on the tester illuminate? | -- | Go to Step 15 | Go to Step 9 | ||||||||||||
9 |
Does the voltage measure greater than the specified value? | 0.5 V | Go to Step 11 | Go to Step 10 | ||||||||||||
Does the voltage measure greater than the specified value? | 0.5 V | Go to Step 12 | Go to Step 16 | |||||||||||||
11 | Repair the high resistance or an open in the output circuit of the generator. Refer to Circuit Testing and Connector Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 16 | -- | ||||||||||||
12 | Repair the high resistance or open in the ground circuit of the generator. Refer to Circuit testing and Connector Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 16 | -- | ||||||||||||
13 |
Does the red DIAGNOSTIC lamp illuminate? | -- | Go to Step 15 | Go to Step 14 | ||||||||||||
14 | There is a problem with the J 41450-B . Refer to the manufacturers instructions, how to test the J 41450-B for proper operation. Has the J 41450-B tester been replaced? | -- | Go to Step 3 | -- | ||||||||||||
15 | Replace the generator. Refer to Generator Replacement Generator Replacement. Did you complete the replacement? | -- | Go to Step 16 | -- | ||||||||||||
16 | Operate the vehicle in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |