Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DEFINITION:
| ||||||||||||||
1 | Did you review the HVAC blower operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms | ||||||||||
2 |
Does the blower motor operate? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | ||||||||||
3 |
Does the test lamp illuminate? | -- | Go to Step 14 | Go to Step 4 | ||||||||||
4 | Connect a J 35616-200 unpowered test lamp between auxiliary blower motor resistor cavity A for CKT 1176 (YEL) and ground. Refer to Circuit Testing in Wiring Systems. Does the test lamp illuminate? | -- | Go to Step 15 | Go to Step 5 | ||||||||||
5 | Connect a J 35616-200 unpowered test lamp between auxiliary blower motor resistor connector cavity C for CKT 1072 (LT BLU) and ground. Refer to Circuit Testing in Wiring Systems. Does the test lamp illuminate? | -- | Go to Step 16 | Go to Step 6 | ||||||||||
6 |
Does the auxiliary blower motor operate? | -- | Go to Step 7 | Go to Step 9 | ||||||||||
7 | Disconnect the front auxiliary HVAC control module. Does the auxiliary blower motor cease operating? | -- | Go to Step 20 | Go to Step 8 | ||||||||||
8 |
Is continuity present? | -- | Go to Step 17 | Go to Step 21 | ||||||||||
9 | Connect the auxiliary blower motor medium speed relay. Does the auxiliary blower motor operate? | -- | Go to Step 10 | Go to Step 12 | ||||||||||
10 | Disconnect the front auxiliary HVAC control module. Does the auxiliary blower motor cease operating? | -- | Go to Step 20 | Go to Step 11 | ||||||||||
11 |
Is continuity present? | -- | Go to Step 18 | Go to Step 22 | ||||||||||
12 |
Is continuity present? | -- | Go to Step 19 | Go to Step 13 | ||||||||||
13 | Connect a J 39200 DMM between front auxiliary HVAC control module pin D and pin F. Refer to Circuit Testing in Wiring Systems. Is continuity present? | -- | Go to Step 20 | Go to Step 23 | ||||||||||
14 | Repair the short to voltage in CKT 1172 (YEL) between the auxiliary blower motor connector, auxiliary blower motor resistor connector, and the auxiliary blower motor high speed relay connector. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 24 | -- | ||||||||||
15 | Repair the short to voltage in CKT 1176 (YEL) between the auxiliary blower motor resistor connector and the auxiliary blower motor low speed relay connector. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 24 | -- | ||||||||||
16 | Repair the short to voltage in CKT 1072 (LT BLU) between the auxiliary blower motor resistor connector and the auxiliary blower motor medium speed relay connector. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 24 | -- | ||||||||||
17 | Repair the short to ground in CKT 1926 (DK BLU)/CKT 60 (YEL) between the front auxiliary HVAC control module connector and the auxiliary blower motor low speed relay connector. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair ? | -- | Go to Step 24 | -- | ||||||||||
18 | Repair the short to ground in CKT 1925 (RED)/63 (TAN) between the front auxiliary HVAC control module connector and the auxiliary blower motor medium speed relay connector. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 24 | -- | ||||||||||
19 | Repair the short to ground in CKT 1924 (WHT)/CKT 52 (ORN) between the front auxiliary HVAC control module connector and the auxiliary blower motor high speed relay connector. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 24 | -- | ||||||||||
20 | Replace the front auxiliary HVAC control module. Refer to Auxiliary Air Conditioning (A/C) Control Assembly Replacement - Front . Did you complete the repair? | -- | Go to Step 24 | -- | ||||||||||
21 | Replace the auxiliary blower motor low speed relay. Did you complete the repair? | -- | Go to Step 24 | -- | ||||||||||
22 | Replace the auxiliary blower motor medium speed relay. Did you complete the repair? | -- | Go to Step 24 | -- | ||||||||||
23 | Replace the auxiliary blower motor high speed relay. Did you complete the repair? | -- | Go to Step 24 | -- | ||||||||||
24 | Operate the auxiliary blower motor in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |
Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DEFINITION:
| ||||||||||||||
1 | Did you review the HVAC blower operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms | ||||||||||
2 |
Does the blower motor operate? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | ||||||||||
3 |
Does the test lamp light? | -- | Go to Step 16 | Go to Step 4 | ||||||||||
4 | Connect a J 35616-200 unpowered test lamp between auxiliary blower motor resistor cavity A for CKT 1176 (YEL) and ground. Does the test lamp light? | -- | Go to Step 17 | Go to Step 5 | ||||||||||
5 | Connect a J 35616-200 unpowered test lamp between auxiliary blower motor resistor connector cavity C for CKT 1072 (LT BLU) and ground. Does the test lamp light? | -- | Go to Step 18 | Go to Step 6 | ||||||||||
6 |
Does the auxiliary blower motor operate? | -- | Go to Step 7 | Go to Step 10 | ||||||||||
7 | Disconnect the front auxiliary HVAC control module. Does the auxiliary blower motor cease operating? | -- | Go to Step 19 | Go to Step 8 | ||||||||||
8 | Disconnect the rear auxiliary HVAC control module. Does the auxiliary blower motor cease operating? | -- | Go to Step 20 | Go to Step 9 | ||||||||||
9 |
Is continuity present? | -- | Go to Step 21 | Go to Step 22 | ||||||||||
10 | Connect the auxiliary blower motor medium speed relay. Does the auxiliary blower motor operate? | -- | Go to Step 11 | Go to Step 14 | ||||||||||
11 | Disconnect the front auxiliary HVAC control module. Does the auxiliary blower motor cease operating? | -- | Go to Step 19 | Go to Step 12 | ||||||||||
12 | Disconnect the rear auxiliary HVAC control module. Does the auxiliary blower motor cease operating? | -- | Go to Step 20 | Go to Step 13 | ||||||||||
13 |
Is continuity present? | -- | Go to Step 23 | Go to Step 24 | ||||||||||
14 |
Is continuity present? | -- | Go to Step 15 | Go to Step 19 | ||||||||||
15 |
Is continuity present? | -- | Go to Step 25 | Go to Step 26 | ||||||||||
16 | Repair the short to voltage in CKT 1172 (YEL) between the auxiliary blower motor connector, auxiliary blower motor resistor connector, and the auxiliary blower motor high speed relay connector. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 27 | -- | ||||||||||
17 | Repair the short to voltage in CKT 1176 (YEL) between the auxiliary blower motor resistor connector and the auxiliary blower motor low speed relay connector. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 27 | -- | ||||||||||
18 | Repair the short to voltage in CKT 1072 (LT BLU) between the auxiliary blower motor resistor connector and the auxiliary blower motor medium speed relay connector. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 27 | -- | ||||||||||
19 | Replace the front auxiliary HVAC control module. Refer to Auxiliary Air Conditioning (A/C) Control Assembly Replacement - Front . Is the repair complete? | -- | Go to Step 27 | -- | ||||||||||
20 | Replace the rear auxiliary HVAC control module. Refer to Control Assembly Replacement - Auxiliary in Overhead Console . Is the repair complete? | -- | Go to Step 27 | -- | ||||||||||
21 | Repair the short to ground in CKT 1926 (DK BLU)/60 (YEL) between the following components:
Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 27 | -- | ||||||||||
22 | Replace the auxiliary blower motor low speed relay. Is the repair complete? | -- | Go to Step 27 | -- | ||||||||||
23 | Repair the short to ground in CKT 1925 (RED)/63 (TAN) between the following components:
Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 27 | -- | ||||||||||
24 | Replace the auxiliary blower motor medium speed relay. Is the repair complete? | -- | Go to Step 27 | -- | ||||||||||
25 | Repair the short to ground in CKT 1924 (WHT)/52 (ORN) between the following components:
Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 27 | -- | ||||||||||
26 | Replace the auxiliary blower motor high speed relay. Is the repair complete? | -- | Go to Step 27 | -- | ||||||||||
27 | Operate the auxiliary blower motor in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |