Circuit Description

When you turn the ignition switch to the RUN position, the GAUGES Fuse applies voltage to the AIR BAG warning lamp that is connected to the inflatable restraint sensing and diagnostic module (SDM) at terminal 7. The inflatable restraint sensing and diagnostic module (SDM) is supplied IGNITION 1 voltage at terminal 10 via the AIR BAGS Fuse when the ignition switch is in the RUN position. The inflatable restraint sensing and diagnostic module (SDM) responds by flashing the AIR BAG warning lamp 7 times. If IGNITION 1 voltage is outside of the normal operating voltage range (8.2-17.1 volts), the AIR BAG warning lamp will come ON solid with no DTCs set.

Test Description

The numbers below refer to the step numbers on the diagnostic table:

  1. This test determines whether the malfunction is in the inflatable restraint sensing and diagnostic module (SDM) circuitry or in the instrument cluster power feed circuitry.

  2. This test determines whether voltage is present in the warning lamp circuit.

  3. This test isolates CKT 358 and inspects for a short in CKT 358 to B+.

  4. This test determines if the malfunction is in the instrument cluster connector.

  5. This test determines if the open is due to a bad bulb.

  6. This test isolates an open in the warning lamp circuitry.

  7. This test inspects whether power is available to the instrument cluster power feed circuit.

  8. This test inspects for a short from the instrument cluster power feed circuit to ground.

  9. This test determines whether the short to ground is due to a short in the wiring or internal to the instrument cluster.

  10. This test determines if the malfunction is in the instrument cluster connector.

  11. This test determines whether the malfunction is due to an open power feed circuit from the GAUGES Fuse.

Air Bag Warning Lamp Does Not Come On

Step

Action

Value(s)

Yes

No

1

Was the SIR Diagnostic System Check performed?

--

Go to Step 2

Go to Diagnostic System Check - SIR

2

  1. Set the parking brake.
  2. Turn the ignition switch to the RUN position.

Does the BRAKE indicator illuminate?

--

Go to Step 3

Go to Step 13

3

  1. Turn the ignition switch to the OFF position.
  2. Disconnect the inflatable restraint steering wheel and IP module yellow 2-way connectors at the base of the steering column and behind the passenger knee bolster.
  3. Disconnect the inflatable restraint sensing and diagnostic module (SDM). Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement .
  4. Install the J 38715-96 SIR Shorting Bar Tool.
  5. Install the CPA.
  6. Turn the ignition switch to the RUN position.
  7. Measure the voltage on the SDM harness connector from terminal 7 to ground.

Is the voltage more than the specified value?

10.0 V

Go to Step 4

Go to Step 6

4

  1. Turn the ignition switch to the OFF position.
  2. Disconnect the instrument cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gauges and Console.
  3. Turn the ignition switch to the RUN position.
  4. Measure the voltage on the SDM harness connector from terminal 7 to ground.

Is the voltage less than the specified value?

1.0 V

Go to Sensing and Diagnostic Module Integrity Check

Go to Step 5

5

  1. Turn the ignition switch to the OFF position.
  2. Repair a short to B+ condition in CKT 358.
  3. Reconnect the instrument cluster.

Is the repair complete?

--

Go to Step 24

--

6

  1. Turn the ignition switch to the OFF position.
  2. Remove the instrument cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gauges and Console.
  3. Inspect for proper connection to the instrument cluster at terminal B17.

Is the connector damaged or corroded?

--

Go to Step 7

Go to Step 8

7

Repair the instrument cluster harness connector. Refer to Connector Repairs in Wiring Systems.

Is the repair complete?

--

Go to Step 24

--

8

  1. Remove the AIR BAG warning lamp bulb. Refer to Instrument Cluster Bulb Replacement in Instrument Panel, Gauges and Console.
  2. Inspect the AIR BAG warning lamp bulb.

Is the bulb good?

--

Go to Step 10

Go to Step 9

9

  1. Replace the AIR BAG warning lamp bulb. Refer to AIR BAG Indicator Replacement .
  2. Install the instrument cluster.

Is the repair complete?

--

Go to Step 24

--

10

  1. Install the AIR BAG warning lamp bulb.
  2. Measure the resistance from the instrument cluster harness connector terminal A16 to the SDM harness connector terminal 7.

Is the resistance within the specified values?

0-5 ohms

Go to Step 12

Go to Step 11

11

  1. Repair an open condition or high resistance in CKT 358.
  2. Install the instrument cluster.

Is the repair complete?

--

Go to Step 24

--

12

Service the instrument cluster. Refer to Diagnostic Starting Point in Instrument Panel, Gauges and Console.

Is the repair complete?

--

Go to Step 24

--

13

  1. Turn the ignition switch to the OFF position.
  2. Remove the GAUGES Fuse.
  3. Inspect the fuse.

Is the fuse good?

--

Go to Step 19

Go to Step 14

14

  1. Replace the fuse.
  2. Turn the ignition switch to the RUN position for 10 seconds.
  3. Turn the ignition switch to the OFF position.
  4. Remove the GAUGES Fuse.
  5. Inspect the fuse.

Is the fuse good?

--

Go to Step 18

Go to Step 15

15

  1. Disconnect the inflatable restraint steering wheel and IP module yellow 2-way connectors at the base of the steering wheel and behind the passenger knee bolster.
  2. Disconnect the instrument cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gauges and Console.
  3. Replace the GAUGES Fuse.
  4. Turn the ignition switch to the RUN position for 10 seconds.
  5. Turn the ignition switch to the OFF position.
  6. Remove the GAUGES Fuse.
  7. Inspect the fuse.

Is the fuse good?

--

Go to Step 17

Go to Step 16

16

  1. Repair a short to ground condition in CKT 39.
  2. Replace the GAUGES Fuse.

Is the repair complete?

--

Go to Step 24

--

17

  1. Service the instrument cluster. Refer to Diagnostic Starting Point in Instrument Panel, Gauges and Console.
  2. Install the GAUGES Fuse.

Is the repair complete?

--

Go to Step 24

--

18

Install the GAUGES Fuse.

Is the repair complete?

--

Go to Step 24

--

19

  1. Remove the instrument cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gauges and Console.
  2. Inspect for proper connection to the instrument cluster at terminal B17.

Is the connector damaged or corroded?

--

Go to Step 20

Go to Step 21

20

Repair the instrument cluster harness connector. Refer to Connector Repairs in Wiring Systems.

Is the repair complete?

--

Go to Step 24

--

21

Measure the resistance between the instrument cluster harness connector terminal B17 to each terminal of the GAUGES Fuse fuseholder.

Is either reading within the specified values?

0-5 ohms

Go to Step 23

Go to Step 22

22

  1. Repair an open condition in CKT 39.
  2. Install the GAUGES Fuse.

Is the repair complete?

--

Go to Step 24

--

23

  1. Repair an open condition in the power feed to the GAUGES Fuse.
  2. Install the GAUGES Fuse.

Is the repair complete?

--

Go to Step 24

--

24

  1. Reconnect all SIR system components.
  2. Verify that all components, connectors and CPAs are properly mounted.

Have all SIR components been reconnected and properly mounted?

--

Go to Diagnostic System Check - SIR

--