Removal Procedure
- Remove the bolt for the
secondary air injection (AIR) crossover bank 1 bracket.
- Disconnect the AIR crossover
bank 1 hose.
- Disconnect the AIR pump
output hose at the AIR valve.
- Disconnect the bank 2
AIR pipe at the AIR valve.
- Remove the AIR valve bracket
bolt.
- Remove the valve from the bracket.
Installation Procedure
- Install the AIR valve
to the bracket.
- Install the AIR valve bracket bolt.
- Connect the bank 2 AIR
pipe.
- Connect the AIR pump output
hose to the AIR valve.
- Connect the AIR crossover
bank 1 hose.
- Install the bolt for the
AIR crossover bank 1 hose bracket