Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: Items powered through the auxiliary power outlets do not operate. | ||||
1 | Did you review the auxiliary power outlet description and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Plug the item into the auxiliary power outlet, and operate the item. Does the item work? | -- | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 5 |
4 | Connect a digital multimeter (DMM) between the auxiliary power outlet connector, cavity B for CKT 150 (BLK), and ground. Refer to Circuit Testing in Wiring Systems. Is continuity present? | -- | Go to Step 7 | Go to Step 6 |
5 | Repair the open in CKT 840 (ORN) between the IP fuse block and the auxiliary power outlet. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 8 | Go to Step 3 |
6 | Repair the open in CKT 150 (BLK) between the auxiliary power outlet and ground G201. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 8 | Go to Step 3 |
7 | Replace the auxiliary power outlet. Is the repair complete? | -- | Go to Step 8 | Go to Step 3 |
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |