Security Data
Auto Learn Timer: The scan tool displays the seconds used by the Passlock™
module to learn valid code from the Passlock™ sensor. The learn procedure
consists of 3 consecutive periods.
Battery Voltage: The scan tool displays the battery system voltage.
Ignition 1: The scan tool displays the state of the ignition switch. The scan
tool displays ACTIVE when the ignition switch is in the RUN or CRANK position.
Ignition 3: The scan tool displays the state of the ignition switch. The scan
tool displays ACTIVE when the ignition switch is in the RUN position.
Passlock™ Code: The scan tool displays the validity of the Passlock™ code
received by the Passlock™ module. The scan tool displays OPEN, SHORTED,
TAMPER and a valid code as a numeric value (1-10).
Passlock™ Data Voltage: The scan tool displays the voltage code from the Passlock™
sensor to the Passlock™ module. The Passlock™ module determines
if the voltage received is a valid or invalid code voltage.
Passlock™ Power: The scan tool displays the 12v reference voltage at the Passlock™
module. The Passlock™ module determines if the monitored voltage is
valid or invalid.
Passlock™ State: The scan tool displays the state of the Passlock™ system.
Security Lamp Feedback: The scan tool displays the feedback voltage at the Passlock™
module. The Passlock™ module determines if the monitored voltage is
valid or invalid.
Security Lamp State: The scan tool displays the state of the SECURITY lamp. The scan
tool displays ON, OFF or FLASHING.
Tamper Timer: The scan tool displays the time remaining when in the tamper mode.
The timer starts when the ignition switch is turned to the RUN position and
the Passlock™ module receives a Passlock™ data voltage different
from the last learned voltage. The timer has a delay of 10 minutes and will
stay active even if the ignition switch is cycled from the RUN
to the OFF position.