Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the bolts and studs to 47 N·m (35 lb ft).
Connect the battery negative cables to the battery terminals. Refer to Battery Negative Cable Disconnection and Connection in Engine Electrical.
13.1. | Remove the cap from the surge tank. |
13.2. | Remove the bleed screw, a slotted screw, from the top of the thermostat housing. |
13.3. | Pour anti-freeze into the surge tank, and watch for a of anti-freeze from the bleed screw. |
13.4. | When a constant flow of anti-freeze is reached, closed the bleed screw at the top of the thermostat housing. |
13.5. | Continue to fill the surge tank to the proper level. |
13.6. | Install the cap on the surge tank. |