Removal Procedure
- Remove the drive belt.
Refer to one of the following procedures:
- Install a T-50® TORX bit into the generator shaft.
- Remove the generator shaft nut and washer.
- Remove the generator pulley.
Installation Procedure
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the generator pulley, washer and shaft nut.
Tighten
Tighten the generator shaft nut to 75 N·m (55 lb ft).
- Install the drive belt. Refer to one of the following
procedures: