1.1. | Submerge the oil pump in a container with clean motor oil. |
1.2. | Rotate the oil pump hex drive by hand until the oil begins to flow from the oil pump assembly. |
1.3. | Clean the excess motor oil from the outside of the oil pump assembly. |
Important: When servicing the oil pump assembly, always replace the retainer between the oil pump hex drive and the oil pump.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the bolts to 90 N·m (65 lb ft).