Tools Required
J 39400-A Halogen
Leak Detector
Removal Procedure
- Recover the refrigerant.
Refer to
Refrigerant Recovery and Recharging
.
- For compression-style fittings; use a back-up wrench on the A/C
refrigerant component (smaller size) fitting (2), then loosen the A/C refrigerant
hose (larger size) fitting (1).
- For banjo-style fittings; remove the bolt retaining the A/C refrigerant
hose to the A/C refrigerant component.
Important: Cap or tape the open A/C refrigerant hose and the A/C refrigerant component
immediately.
- Disconnect the A/C refrigerant hose from the A/C refrigerant component,
discard the O-ring seal and cap or tape the A/C refrigerant hose and the A/C
refrigerant component to prevent contamination.
Installation Procedure
- Remove the cap or tape
from the A/C refrigerant hose and the A/C refrigerant component.
- Using a lint-free clean, dry cloth, carefully clean the sealing
surfaces of the A/C refrigerant hose and the A/C refrigerant component.
- Lightly coat the new O-ring seal (1) with mineral base 525 viscosity
refrigerant oil.
Important: DO NOT allow any of the mineral base 525 viscosity refrigerant
oil on the new O-ring seal to enter the refrigerant system.
- For compression-style fittings; carefully slide the new O-ring seal
(1) onto the A/C refrigerant hose until seated.
- For banjo-style fittings;
carefully slide the new O-ring seal (1) onto the A/C refrigerant hose until
seated.
Leave a light coating of the refrigerant oil to remain on the A/C refrigerant
hose in the area indicated (2) ONLY.
- Install the A/C refrigerant
hose to the A/C refrigerant component.
- For compression-style fittings; use a back-up wrench on the A/C
refrigerant component (smaller size) fitting (2), then tighten the A/C refrigerant
hose (larger size) fitting (1) to specification.
- For banjo-style fittings; install the bolt retaining the A/C refrigerant
hose to the A/C refrigerant component, then tighten to specification.
- Evacuate and charge the refrigerant system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fitting(s) of the repaired or reinstalled component
using the J 39400-A
.