Step | Action | Yes | No |
---|---|---|---|
DEFINITION: Noise originating from the blower motor. | |||
1 | Were you sent here from the HVAC Symptoms? | Go to Step 2 | Go to Symptoms - HVAC Systems - Manual in HVAC Systems-Manual |
2 |
Is a noise evident during the blower operation? | Go to Step 3 | -- |
3 | Does the noise vary with the blower speed? | Go to Step 4 | -- |
4 | Inspect for excessive vibration at each blower motor speed by feeling the blower case. Is excessive vibration present? | Go to Step 5 | -- |
5 | Remove the blower motor. Refer to Blower Motor Replacement . Inspect the blower motor for deposits of foreign material. Is there foreign material on the blower motor? | Go to Step 7 | Go to Step 6 |
6 | Inspect the blower motor for the following:
Were any of these conditions found? | Go to Step 8 | -- |
7 | Remove the foreign material. Is the action complete? | Go to Step 9 | -- |
8 | Replace the blower motor. Refer to Blower Motor Replacement . Is the replacement complete? | Go to Step 9 | -- |
9 | Operate the system in order to verify the repair. Did you find and correct the condition? | System OK | Go to Step 2 |