Table 1: | A/C Performance Table -- with Front A/C |
Table 2: | A/C Performance Table -- with Rear A/C |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F), 345 kPa (50 psi) More than 24°C (75°F), 483 kPa (70 psi) More than 33°C (90°F), 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 4 | Go to Step 3 | |||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-16°C (55-65°F) | 0-100% | 175-192 kPa (25-28 psi) | 500-840 kPa (73-122 psi) | 6°C (43°F) |
19-24°C (66-75°F) | Below 40% | 175-207 kPa (25-30 psi) | 720-1090 kPa (105-158 psi) | 6°C (43°F) |
Above 40% | 175-232 kPa (25-34 psi) | 740-1120 kPa (107-163 psi) | 8°C (46°F) | |
25-29°C (76-85°F) | Below 35% | 175-238 kPa (25-35 psi) | 1000-1320 kPa (145-192 psi) | 9°C (48°F) |
35-60% | 175-244 kPa (25-35 psi) | 1010-1330 kPa (147-193 psi) | 9°C (48°F) | |
Above 60% | 175-257 kPa (27-37 psi) | 1020-1360 kPa (148-197 psi) | 11°C (52°F) | |
30-35°C (86-95°F) | Below 30% | 190-279 kPa (28-41 psi) | 1230-1590 kPa (179-231 psi) | 12°C (54°F) |
30-50% | 196-282 kPa (28-41 psi) | 1240-1610 kPa (180-234 psi) | 12°C (54°F) | |
Above 50% | 204-286 kPa (30-42 psi) | 1250-1640 kPa (181-238 psi) | 13°C (55°F) | |
36-41°C (96-105°F) | Below 20% | 235-322 kPa (34-47 psi) | 1500-1860 kPa (218-270 psi) | 15°C (59°F) |
20-40% | 237-320 kPa (34-47 psi) | 1510-1880 kPa (219-273 psi) | 15°C (59°F) | |
Above 40% | 240-318 kPa (35-47 psi) | 1520-1900 kPa (221-276 psi) | 16°C (61°F) | |
42-46°C (106-115°F) | Below 20% | 283-359 kPa (41-52 psi) | 1770-2090 kPa (257-303 psi) | 18°C (64°F) |
Above 20% | 282-353 kPa (41-51 psi) | 1780-2110 kPa (235-306 psi) | 18°C (64°F) | |
47-49°C (116-120°F) | Below 30% | 319-377 kPa (46-55 psi) | 2010-2240 kPa (292-325 psi) | 20°C (68°F) |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Discharge Air Temperature | ||
---|---|---|---|---|---|
Low Side | High Side | Left Center | Rear Center | ||
13-18°C (55-65°F) | 0-100% | 175-205 kPa (25.4-29.8 psi) | 420-860 kPa (61-124.8 psi) | 6°C (42.8°F) | 9°C (48.2°F) |
19-24°C (66-75°F) | Below 40% | 175-240 kPa (25.4-34.8 psi) | 610-1080 kPa (88.5-156.7 psi) | 8°C (46.4°F) | 11°C (51.8°F) |
Above 40% | 175-267 kPa (25.4-38.8 psi) | 680-1170 kPa (98.7-169.8 psi) | 10°C (50°F) | 13°C (55.4°F) | |
25-29°C (76-85°F) | Below 35% | 184-284 kPa (26.7-41.2 psi) | 940-1330 kPa (136.4-193 psi) | 11°C (51.8°F) | 14°C (57.2°F) |
35-50% | 197-293 kPa (28.6-42.5 psi) | 990-1360 kPa (143.7-197.4 psi) | 12°C (53.6°F) | 15°C (59°F) | |
Above 50% | 207-310 kPa (30-45 psi) | 1020-1430 kPa (148-207.5 psi) | 13°C (55.4°F) | 16°C (60.8°F) | |
30-35°C (86-95°F) | Below 30% | 233-339 kPa (33.8-49.2 psi) | 1210-1640 kPa (175.6-238 psi) | 15°C (59°F) | 18°C (64.4°F) |
30-50% | 241-348 kPa (35-50.5 psi) | 1240-1680 kPa (180-243.8 psi) | 16°C (60.8°F) | 19°C (66.2°F) | |
Above 50% | 253-362 kPa (36.7-52.5 psi) | 1280-1730 kPa (185.8-251.1 psi) | 18°C (64.4°F) | 21°C (69.8°F) | |
36-41°C (96-105°F) | Below 20% | 289-392 kPa (41.9-56.9 psi) | 1520-1940 kPa (220.6-281.6 psi) | 19°C (66.2°F) | 21°C (69.8°F) |
20-40% | 294-399 kPa (42.7-57.9 psi) | 1540-1980 kPa (223.5-287.4 psi) | 20°C (68°F) | 22°C (71.6°F) | |
Above 40% | 303-407 kPa (44-59.1 psi) | 1580-2010 kPa (229.3-293.7 psi) | 21°C (69.8°F) | 24°C (75.2°F) | |
42-46°C (106-115°F) | Below 20% | 348-440 kPa (50.5-63.9 psi) | 1840-2210 kPa (267.1-320.8 psi) | 23°C (73.4°F) | 24°C (75.2°F) |
Above 20% | 352-446 kPa (51.1-64.7 psi) | 1860-2240 kPa (270-325.1 psi) | 24°C (75.2°F) | 26°C (78.8°F) | |
47-49°C (116-120°F) | Below 30% | 400-472 kPa (58.1-68.5 psi) | 2130-2380 kPa (309.1-345.4 psi) | 25°C (77°F) | 27°C (80.6°F) |