Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: The auxiliary blower motor is inoperative in all speed positions. | |||
1 | Did you review the HVAC operation and perform the necessary inspections? | Go to Step 2 | |
2 |
Is the auxiliary blower motor inoperative in all speed positions? | Go to Step 4 | Go to Step 3 |
3 |
Is the auxiliary blower motor inoperative in all speed positions? | Go to Step 9 | |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 6 |
5 |
Does the test lamp illuminate? | Go to Step 10 | Go to Step 12 |
6 | Test the auxiliary blower motor supply voltage circuit for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 7 |
7 | Test the ignition 3 voltage circuit to the auxiliary blower motor relays for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 8 |
8 | Test the battery positive voltage circuit to the auxiliary blower motor relays for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 9 |
9 | Test the ground circuit of the auxiliary blower motor switch (auxiliary heat only) or front auxiliary HVAC control assembly (auxiliary heat and A/C) for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 11 |
10 | Inspect for poor connections at the harness connector of the auxiliary blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 13 |
11 | Inspect for poor connections at the harness connector of the auxiliary blower motor switch (auxiliary heat only) or front auxiliary HVAC control assembly (auxiliary heat and A/C). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 14 |
12 | Repair the ground circuit of auxiliary blower motor. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 15 | -- |
13 | Replace auxiliary blower motor. Refer to Auxiliary Blower Motor Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 15 | -- |
14 | Replace the auxiliary blower motor switch (auxiliary heat only) or the front auxiliary HVAC control assembly (auxiliary heat and A/C). Refer to Auxiliary Blower Motor Switch Replacement or Auxiliary Heater and Air Conditioning Control Replacement - Front . Did you complete the repair? | Go to Step 15 | -- |
15 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |