Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Exterior Lights Schematics | |||
1 | Did you review the backup lamp operation and perform the necessary inspections? | Go to Step 2 | Go to Exterior Lighting Systems Description and Operation in Wiring Systems |
2 | Operate the backup lamp(s) to verify the fault is present. Does the system operate normally? | Go to Testing for Electrical Intermittents in Wiring Systems | Go to Step 3 |
3 |
Is the back-up lamp(s) on? | Go to Step 5 | Go to Step 4 |
4 | Inspect for poor connections at the harness connector of the back-up lamp switch. Did you find and correct the condition? | Go to Step 7 | Go to Step 6 |
5 | Repair the backup lamp supply voltage circuit for a short to voltage. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 7 | -- |
6 | Replace the backup lamp switch. Refer to Park/Neutral Position Switch Replacement in Automatic Transmission-4L60-E, or Park/Neutral Position Switch Replacement in Automatic Transmission-4L80-E. Did you complete the replacement? | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |