The EVAP LARGE LEAK TEST applies vacuum to the evaporative emission (EVAP) system and monitors vacuum decay. The control module uses the input from the fuel tank pressure (FTP) sensor in order to determine the rate of vacuum decay. At an appropriate time, the control module turns the EVAP canister purge valve ON (open) and the EVAP canister vent valve ON (closed). This allows the engine to draw a vacuum on the system. At a calibrated time or vacuum level, the control module turns the purge valve OFF (closed), and tests the system vacuum. If the system is unable to achieve the calibrated vacuum control module, DTC P0440 will set.
• | DTC P0107, P0108, P0112, P0113, P0117, P0118, P0121, P0122, P0123, P0125, P0443, P0449, P0452, P0453, P1111, P1112, P1114, P1115, P1121 or P1122 are not set. |
• | The system voltage is between 10-18 volts. |
• | The startup engine coolant temperature (ECT) is between 4-30°C (39-86°F). |
• | The startup intake air temperature (IAT) is between 4-30°C (39-86°F). |
• | The start up ECT and IAT are within 9°C (16°F) of each other. |
• | The fuel tank level is between 15-85 percent. |
• | The barometric pressure (BARO) is more than 75 kPa. |
• | The vehicle speed sensor (VSS) is less than 121 km/h (75 mph). |
The EVAP system is not able to achieve or maintain vacuum during the diagnostic test.
• | The control module illuminates the malfunction indicator lamp (MIL) when the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The control module stores this information in the Freeze Frame/Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
• | Use the J 41413 EVAP Pressure/Purge Diagnostic Station in order to pressurize the EVAP system to aid in locating intermittent leaks. |
Move all EVAP components while testing with the J 41416 Ultrasonic Leak Detector. |
• | A temporary blockage in the EVAP canister purge valve, purge pipe or EVAP canister could cause an intermittent condition. To repair a blockage in the EVAP system refer to Evaporative Emission System Cleaning . |
The numbers below refer to the step numbers on the diagnostic table.
This step verifies that a failure condition is active.
This step is used to verify if a leak is present.
This step verifies proper operation of the fuel tank pressure (FTP) sensor.
This step tests the EVAP canister purge valve for a restriction or blockage.
This step verifies that repairs are complete and that no other condition is present.
Step | Action | Values | Yes | No | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Emission Hose Routing Diagram | ||||||||||||||||||||||||
1 | Did you perform the Diagnostic System Check-Engine Controls? | -- | Go to Step 2 | |||||||||||||||||||||
2 | Does the scan tool indicate DTC P0443 or DTC P0449 are also set? | -- | Go to Step 3 | |||||||||||||||||||||
3 |
Did you find and correct the condition? | -- | Go to Step 19 | Go to Step 4 | ||||||||||||||||||||
Does the scan tool indicate that the Service Bay Test passed? | -- | Go to Diagnostic Aids | Go to Step 5 | |||||||||||||||||||||
Important: Always zero the EVAP pressure and vacuum (in H2O) gauges on the EVAP pressure diagnostic station before proceeding with diagnosis.
Did you obtain the specified value? | 5 in H2O | Go to Step 6 | Go to Step 9 | |||||||||||||||||||||
Compare the J 41413 value to the scan tool fuel tank pressure (FTP) sensor value. Does the J 41413 value measure near the scan tool value? | -- | Go to Step 7 | Go to Step 13 | |||||||||||||||||||||
7 |
Does the EVAP system pressure decrease? | 5 in H2O | Go to Step 8 | Go to Step 10 | ||||||||||||||||||||
8 | Inspect the vacuum source to the EVAP purge valve for blockage, cuts, or disconnects. Repair as necessary. Did you find and correct the condition? | -- | Go to Step 19 | Go to Diagnostic Aids | ||||||||||||||||||||
9 |
Important: It may be necessary to partially lower the fuel tank to inspect components located in the upper portion of the tank.
Did you locate and repair a leak? | -- | Go to Step 19 | Go to Diagnostic Aids | ||||||||||||||||||||
Does the EVAP system pressure decrease? | -- | Go to Step 16 | Go to Step 11 | |||||||||||||||||||||
11 |
Does the EVAP system pressure decrease? | -- | Go to Step 17 | Go to Step 12 | ||||||||||||||||||||
12 |
Does the EVAP system pressure decrease? | -- | Go to Step 18 | Go to Step 15 | ||||||||||||||||||||
13 | Monitor the FTP sensor voltage with a scan tool. Is the FTP sensor voltage more than the specified value? | 4.3 V | Go to DTC P0453 | Go to Step 14 | ||||||||||||||||||||
14 | Replace the fuel tank pressure (FTP) sensor. Refer to Fuel Tank Pressure Sensor Replacement . Did you complete the replacement? | -- | Go to Step 19 | -- | ||||||||||||||||||||
15 | Repair for a pinched or obstructed EVAP vapor pipe between the front and rear tanks. Did you complete the repair? | -- | Go to Step 19 | -- | ||||||||||||||||||||
16 | Replace the EVAP canister purge valve. Refer to Evaporative Emission Canister Purge Solenoid Valve Replacement . Did you complete the replacement? | -- | Go to Step 19 | -- | ||||||||||||||||||||
17 | Repair the restriction in the EVAP purge pipe. Refer to Evaporative Emission System Cleaning . Did you complete the repair? | -- | Go to Step 19 | -- | ||||||||||||||||||||
18 | Replace the EVAP canister. Refer to Evaporative Emission Canister Replacement Did you complete the replacement? | -- | Go to Step 19 | -- | ||||||||||||||||||||
Perform the Service Bay Test. Refer to Service Bay Test . Does the scan tool indicate that the Service Bay Test passed? | -- | Go to Step 20 | Go to Step 2 | |||||||||||||||||||||
20 | With a scan tool, observe the stored information, Capture Info. Does the scan tool display any DTCs that you have not diagnosed? | -- | System OK |