GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

  1. Turn OFF the ignition.
  2. Remove the air cleaner assembly. Refer to Air Cleaner Assembly Replacement .

  3. Object Number: 281993  Size: SH

    Important: Carefully note the position of the exhaust gas recirculation (EGR) valve before removal. Do not rotate the EGR valve 180 degrees.

  4. Remove the EGR valve harness connector.
  5. Notice: The Linear EGR valve is an electrical component. DO NOT soak in any liquid cleaner or solvent because damage may result.


    Object Number: 22075  Size: SH
  6. Remove the EGR valve to flange attaching bolts.

  7. Object Number: 22078  Size: SH

    Important: Do not try to disassemble the linear EGR valve. Service only as a complete assembly.

  8. Remove the linear EGR valve.
  9. Remove the flange gasket.
  10. Clean the linear EGR valve gasket surface.

Installation Procedure


    Object Number: 22078  Size: SH
  1. Install the new flange gasket
  2. Install the linear EGR valve.

  3. Object Number: 22075  Size: SH

    Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  4. Install the valve to flange bolts.
  5. Tighten

    1. Tighten the bolts the first time to 10 N·m (89 lb in) each.
    2. Tighten the bolts a final time to 25 N·m (18 lb ft) each.

    Object Number: 281993  Size: SH
  6. Install the EGR valve harness connector.
  7. Install the air cleaner assembly. Refer to Air Cleaner Assembly Replacement .