The information in this table is intended for use with the J 33431-C Signal Generator and Instrument Panel Tester. The fuel level sensor values represent the test values to be used on the Signal Generator to drive the fuel gage display to the indicated positions. Vehicles that require more than one fuel level sensor calculate gage position from many possible resistance combinations of fuel levels between the two tanks. Therefore, the values in the table may not correlate directly to readings taken from the vehicle primary or secondary sending units.
The values in the table are approximate values based on information obtained from properly operating vehicles. Actual results may vary slightly.
Fuel Gage Display | Resistance | Voltage | Fuel Level | Fuel Remaining |
---|---|---|---|---|
31 Gallon Tank | ||||
E | 51 ohms | 0.8 V | 8% | 15 L (4 gal) |
1/4 | 110 ohms | 1.5 V | 35% | 45 L (12 gal) |
1/2 | 135 ohms | 1.7 V | 46% | 61 L (16 gal) |
3/4 | 165 ohms | 2.0 V | 60% | 76 L (20 gal) |
F | 232 ohms | 2.4 V | 86% | 102 L (27 gal) |
35 Gallon Tank | ||||
E | 48 ohms | 0.8 V | 8% | 9 L (3 gal) |
1/4 | 117 ohms | 1.6 V | 31% | 47 L (13 gal) |
1/2 | 145 ohms | 1.8 V | 45% | 68 L (18 gal) |
3/4 | 183 ohms | 2.1 V | 65% | 91 L (24 gal) |
F | 226 ohms | 2.4 V | 90% | 114 L (30 gal) |
55 Gallon Tank | ||||
E | 85 ohms | 1.27 V | 0-5% | 53 L (14 gal) |
1/4 | 161 ohms | 1.96 V | 23-27% | 123 L (33 gal) |
1/2 | 203 ohms | 2.25 V | 63-68% | 161 L (43 gal) |
3/4 | 232 ohms | 2.43 V | 79-83% | 184 L (49 gal) |
F | 250 ohms | 2.51 V | 85-89% | 189 L (50 gal) |