Table 1: | Instrument Panel Cluster (IPC) |
Table 2: | Powertrain Control Module (PCM) |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
Lamp Test | Displays Test | The IPC illuminates all of the display segments when you select On. |
IPC Gauges | Displays Test | The IPC drives all gages to the maximum physical position when you select On. The IPC drives all gages to the minimum physical position when you select Off. |
PRNDL Display | Displays Test | The IPC illuminates the PRNDL when you select On. |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
Engine Output Controls | Fuel Gauge | The PCM drives the fuel gage to the maximum physical position when you select On. The PCM drives the fuel gage to the minimum physical position when you select Off. |
Engine Output Controls | Malfunction Indicator Lamp (MIL) | The PCM commands the MIL On and Off. |
Engine Output Controls | Oil Life Reset | The PCM resets the oil life monitor to the desired percent. |