Removal Procedure
- Disconnect the mass air flow (MAF) harness connector.
- Remove the air cleaner assembly hold down screw.
- Loosen the air cleaner outlet duct hose clamp.
- Remove the air cleaner assembly.
Installation Procedure
- Install the air cleaner assembly.
Caution: Refer to Fastener Caution in the Preface section.
- Tighten the air cleaner outlet duct hose clamp to
4 N·m (35 lb in).
- Install the air cleaner assembly hold down screw.
- Connect the MAF harness connector.