Diagnostic Instructions
Circuit/System Description
The Engine Cranks but Does Not Run diagnostic table is an organized approach to identifying a condition that causes an engine not to start. The Engine Cranks but Does Not Run diagnostic table directs the service technician to the appropriate system diagnosis.
The Engine Cranks But Does Not Run diagnostic table assumes the following:
• | There is adequate fuel in the fuel tanks. |
Diagnostic Aids
If the cause of an engine cranks but will not run condition has not been found, inspect for the following conditions:
• | Hard starting only in cold ambient temperatures. These may cause an intermittent condition that may not occur in the service bay: |
- | Ice blockage at the fuel pickup in the fuel tank--This will be a high vacuum in the supply lines while cranking, and the problem will disappear after the vehicle is brought in the service bay. It may also exhibit a start and stall condition
or a starting condition with no acceleration. |
• | The correct cranking speed is 100 RPM cold and 180 RPM hot. |
• | Low engine coolant may cause the engine to shut down. |
Reference Information
Schematic Reference
Engine Controls Schematics
Connector End View Reference
Electrical Information Reference
Scan Tool Reference
Special Tools Required
CH-48027 Digital Pressure Gage
Circuit/System Verification
- If DTCs P0090, P0191, P0193, P0335, P0336, P0340, P0602, P0603, P0604, P0606, P0642, P0643, P064C, P0698, P0699, P2510 are set diagnose those DTCs first.
- The engine starts and runs.
⇒ | If the engine does not start and run perform the Circuit/System Testing. |
Circuit/System Testing
- Inspect for the following conditions:
- Install the
CH-48027 to the fuel rail service port. Crank the engine and observe the fuel pressure gage to ensure fuel pressure is present..
- Engine cranking, verify the scan tool Fuel Rail Pressure Sensor parameter is greater than 10 MPa.
- Perform the Engine Compression Test. Refer to
Engine Compression Test.
Important: During the replacement of the injectors, inspect the inlet and outlet fittings for corrosion or contamination. Refer to
Contaminants-in-Fuel Diagnosis.
⇒ | If any fuel vapor was emitted during the engine compression test, replace the affected fuel injector. Refer to
Fuel Injector Replacement. |
Repair Instructions
Perform the
Diagnostic Repair Verification after completing the diagnostic procedure.
Fuel Injector Replacement
Repair Verification
The engine starts and runs.